In order to establish the potential of [51/52Mn]Cl2 as safe PET brain tracers, the radiation effective dose (ED) of [51Mn]- and [52Mn]-chloride has been assessed by using biokinetic models in anthropomorphic phantoms. Results showed that [52Mn]-chloride releases one hundred thirty times more radiation dose (ED = 1.35 mSv/MBq) than [51Mn]-chloride (ED = 1.02E-02 mSv/MBq). Although the maximum positron energy of 52Mn allows a PET image resolution similar to that of 18F, activities below 15 MBq should be administered.
Radiation effective dose assessment of [51Mn]- and [52Mn]-chloride
Bolzati C;
2019
Abstract
In order to establish the potential of [51/52Mn]Cl2 as safe PET brain tracers, the radiation effective dose (ED) of [51Mn]- and [52Mn]-chloride has been assessed by using biokinetic models in anthropomorphic phantoms. Results showed that [52Mn]-chloride releases one hundred thirty times more radiation dose (ED = 1.35 mSv/MBq) than [51Mn]-chloride (ED = 1.02E-02 mSv/MBq). Although the maximum positron energy of 52Mn allows a PET image resolution similar to that of 18F, activities below 15 MBq should be administered.File in questo prodotto: