Synchrotron radiation (SR)-based X-ray methods are powerful analytical tools for several purposes. They are widely used to probe the degradation mechanisms of inorganic artists' pigments in paintings, including chrome yellows (PbCr1-xSxO4; 0 <= x <= 0.8), a class of compounds often found in Van Gogh masterpieces. However, the high intensity and brightness of SR beams raise important issues regarding the potential damage inflicted on the analyzed samples. A thorough knowledge of the SR X-ray sensitivity of each class of pigment in the painting matrix is therefore required to find analytical strategies that seek to minimize the damage for preserving the integrity of the analyzed samples and to avoid data misinterpretation. Here, we employ a combination of Cr K-edge X-ray absorption near-edge structure spectroscopy, Cr-K? X-ray emission spectroscopy, and X-ray diffraction to monitor and quantify the effects of SR X-rays on the stability of chrome yellows and related Cr compounds and to define mitigation strategies. We found that the SR X-ray beam exposure induces changes in the oxidation state and local coordination environment of Cr ions and leads to a loss of the compound's crystalline structure. The extent of X-ray damage depends on some intrinsic properties of the samples (chemical composition of the pigment and the presence/absence and nature of the binder). It can be minimized by optimizing the overall fluence/dose released to the samples and by working in vacuum and under cryogenic conditions.

Damages Induced by Synchrotron Radiation-Based X-ray Microanalysis in Chrome Yellow Paints and Related Cr-Compounds: Assessment, Quantification, and Mitigation Strategies

Letizia Monico
Primo
;
Costanza Miliani
Ultimo
2020

Abstract

Synchrotron radiation (SR)-based X-ray methods are powerful analytical tools for several purposes. They are widely used to probe the degradation mechanisms of inorganic artists' pigments in paintings, including chrome yellows (PbCr1-xSxO4; 0 <= x <= 0.8), a class of compounds often found in Van Gogh masterpieces. However, the high intensity and brightness of SR beams raise important issues regarding the potential damage inflicted on the analyzed samples. A thorough knowledge of the SR X-ray sensitivity of each class of pigment in the painting matrix is therefore required to find analytical strategies that seek to minimize the damage for preserving the integrity of the analyzed samples and to avoid data misinterpretation. Here, we employ a combination of Cr K-edge X-ray absorption near-edge structure spectroscopy, Cr-K? X-ray emission spectroscopy, and X-ray diffraction to monitor and quantify the effects of SR X-rays on the stability of chrome yellows and related Cr compounds and to define mitigation strategies. We found that the SR X-ray beam exposure induces changes in the oxidation state and local coordination environment of Cr ions and leads to a loss of the compound's crystalline structure. The extent of X-ray damage depends on some intrinsic properties of the samples (chemical composition of the pigment and the presence/absence and nature of the binder). It can be minimized by optimizing the overall fluence/dose released to the samples and by working in vacuum and under cryogenic conditions.
2020
Istituto di Scienze e Tecnologie Chimiche "Giulio Natta" - SCITEC
Inglese
92
20
14164
14173
10
https://pubs.acs.org/doi/full/10.1021/acs.analchem.0c03251
Esperti anonimi
synchrotron radiation
radiation damage
pigments degradation
lead chromate
X-ray spectroscopy
Internazionale
Elettronico
11
info:eu-repo/semantics/article
262
Monico, Letizia; Cotte, Marine; Vanmeert, Frederik; Amidani, Lucia; Janssens, Koen; Nuyts, Gert; Garrevoet, Jan; Falkenberg, Gerald; Glatzel, Pieter; ...espandi
01 Contributo su Rivista::01.01 Articolo in rivista
partially_open
   Integrated Platform for the European Research Infrastructure ON Cultural Heritage
   IPERION CH
   H2020
   654028
File in questo prodotto:
File Dimensione Formato  
Monico et al_AnalChem_2020.pdf

solo utenti autorizzati

Tipologia: Versione Editoriale (PDF)
Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 7.51 MB
Formato Adobe PDF
7.51 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
Monico_2020_Anal Chem_accepted.pdf

Open Access dal 22/09/2021

Descrizione: versione accettata
Tipologia: Documento in Post-print
Licenza: Altro tipo di licenza
Dimensione 3.81 MB
Formato Adobe PDF
3.81 MB Adobe PDF Visualizza/Apri
ac0c03251_si_001.pdf

accesso aperto

Descrizione: SuppInformation
Tipologia: Altro materiale allegato
Licenza: Altro tipo di licenza
Dimensione 1.67 MB
Formato Adobe PDF
1.67 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/393122
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 30
  • ???jsp.display-item.citation.isi??? 27
social impact