The energy calibration and the first experimental measurements of a diagnostic for the neutron-gamma detection are presented. The system is composed of 6 scintillator cells coupled with flat photomultiplier tubes. One detector cell is based on NaI(Tl) crystal scintillator, the remaining ones use EJ-309 organic liquid scintillators. While the former is used for gamma-ray spectra analysis, the latter are used for fast neutron detection, by means of the Pulse Shape Discrimination (PSD) technique. Energy calibration has been performed with several calibrated radioactive sources, the neutron response function has been analyzed as a function of the neutron time-of-flight, using a 252Cf source tagged by an additional fast plastic scintillator. A high neutron flux has been detected in discharges operated with NBI. The overall diagnostic has proved to withstand flows, up to several Mcounts/ms. The diagnostics is able to detect fast transient phenomena, such as those detected during discrete plasma relaxation events. Fast transient peaks have been detected, allowing the study of fast particles induced by magnetic reconnection events in plasma.

New neutron-gamma scintillator diagnostics at the Madison Symmetric Torus

Zuin M;
2019

Abstract

The energy calibration and the first experimental measurements of a diagnostic for the neutron-gamma detection are presented. The system is composed of 6 scintillator cells coupled with flat photomultiplier tubes. One detector cell is based on NaI(Tl) crystal scintillator, the remaining ones use EJ-309 organic liquid scintillators. While the former is used for gamma-ray spectra analysis, the latter are used for fast neutron detection, by means of the Pulse Shape Discrimination (PSD) technique. Energy calibration has been performed with several calibrated radioactive sources, the neutron response function has been analyzed as a function of the neutron time-of-flight, using a 252Cf source tagged by an additional fast plastic scintillator. A high neutron flux has been detected in discharges operated with NBI. The overall diagnostic has proved to withstand flows, up to several Mcounts/ms. The diagnostics is able to detect fast transient phenomena, such as those detected during discrete plasma relaxation events. Fast transient peaks have been detected, allowing the study of fast particles induced by magnetic reconnection events in plasma.
2019
Istituto per la Scienza e Tecnologia dei Plasmi - ISTP
Inglese
61st Annual Meeting of the APS Division of Plasma Physics
http://meetings.aps.org/Meeting/DPP19/Session/GP10.75
October 21-25, 2019
Fort Lauderdale, Florida
Pulse Shape Discrimination
PSD
Madison Symmetric Torus
MST
Abstract: GP10.00075 / https://ui.adsabs.harvard.edu/abs/2019APS..DPPG10075C/abstract
1
info:eu-repo/semantics/conferenceObject
none
274
04 Contributo in convegno::04.02 Abstract in Atti di convegno
Cordaro L.; Zuin M.; Anderson J.; Stevanato L.; Fontana C.; Bonesso I.; Kim J.
   Implementation of activities described in the Roadmap to Fusion during Horizon 2020 through a Joint programme of the members of the EUROfusion consortium
   EUROfusion
   H2020
   633053
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/393508
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact