Spark discharge (SD) laser-induced breakdown spectroscopy (LIBS) is a technique suitable to overcome the low energies of lasers by reheating the plasma, increasing the emission intensities and to perform single-standard calibration. A calibration method called one-point and multi-voltage calibration (OP-MVC), which requires two different voltages applied to both the standard and the sample, is proposed for use with SD-LIBS. The performance of this method was compared to that of the one-point and multi-lines calibration (OP-MLC) and the slope ratio calibration (SRC) methods for LIBS determination of Al in certified reference plant leaves and P in commercial fertilizers. No statistical differences at the 95% confidence level were observed between the Al and P concentrations determined by OP-MVC LIBS for the Al certified values and the P values measured by high-resolution continuum-source flame atomic absorption spectrometry (HR-CS FAAS). The limit of detection (LOD) for P was 0.60 wt% P2O5 and 35.1 mg kg(-1) for Al. The relative standard deviation (n=3) was typically 7% for Al and in the 4 - 10% range for P.

Spark discharge-libs: Evaluation of one-point and multi-voltage calibration for p and al determination

Senesi GS;
2021

Abstract

Spark discharge (SD) laser-induced breakdown spectroscopy (LIBS) is a technique suitable to overcome the low energies of lasers by reheating the plasma, increasing the emission intensities and to perform single-standard calibration. A calibration method called one-point and multi-voltage calibration (OP-MVC), which requires two different voltages applied to both the standard and the sample, is proposed for use with SD-LIBS. The performance of this method was compared to that of the one-point and multi-lines calibration (OP-MLC) and the slope ratio calibration (SRC) methods for LIBS determination of Al in certified reference plant leaves and P in commercial fertilizers. No statistical differences at the 95% confidence level were observed between the Al and P concentrations determined by OP-MVC LIBS for the Al certified values and the P values measured by high-resolution continuum-source flame atomic absorption spectrometry (HR-CS FAAS). The limit of detection (LOD) for P was 0.60 wt% P2O5 and 35.1 mg kg(-1) for Al. The relative standard deviation (n=3) was typically 7% for Al and in the 4 - 10% range for P.
2021
Istituto per la Scienza e Tecnologia dei Plasmi - ISTP
Inglese
42
1
18
24
7
https://www.researchgate.net/profile/Atomic-Spectroscopy/publication/348429340_Spark_Discharge-LIBS_Evaluation_of_One-Point_and_Multi-_Voltage_Calibration_for_P_and_Al_Determination/links/5ffe85f592851c13fe09daeb/Spark-Discharge-LIBS-Evaluation-of-One-Point-and-Multi-Voltage-Calibration-for-P-and-Al-Determination.pdf
Sì, ma tipo non specificato
Induced Breakdown
Spectrscopy
Elemental Analysis
Laser
Emission
Electronic ISSN: 2708-521X - http://www.scopus.com/inward/record.url?eid=2-s2.0-85100838547&partnerID=q2rCbXpz
5
info:eu-repo/semantics/article
262
Vieira, Al; Ferreira, Ec; Junior, Ds; Senesi, Gs; Neto, Jag
01 Contributo su Rivista::01.01 Articolo in rivista
restricted
File in questo prodotto:
File Dimensione Formato  
prod_456989-doc_177117.pdf

solo utenti autorizzati

Descrizione: Spark Discharge-LIBS: Evaluation of One-Point and Multi- Voltage Calibration for P and Al Determination
Tipologia: Versione Editoriale (PDF)
Dimensione 4.73 MB
Formato Adobe PDF
4.73 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/395522
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 10
  • ???jsp.display-item.citation.isi??? 8
social impact