A conceptual design and performance studies for a collimated neutron flux monitor and neutron spectrometer for the Divertor Tokamak Test (DTT) facility are presented. This study is based on the single-null divertor configuration and for "Half Power" and "Full power" scenarios with 15 MW of negative-ion NBI, 29 MW of ECH and 3 MW of ICRF heating with a maximum neutron yield of 1.5 × 1017 s- 1. Fast ion distributions (both from auxiliary heating systems and fusion born) have been simulated in TRANSP/NUBEAM and the corresponding neutron energy spectra have been calculated using DRESS. Synthetic diagnostics have been implemented to determine the neutron fluxes and spectra at the detector location. Neutron emissivity profiles, plasma position, core ion temperature and the ratio of thermal and non-thermal D ion populations can be obtained with good accuracy and time resolution.

Conceptual design of a collimated neutron flux monitor and spectrometer for DTT

Casiraghi I;Mantica P;Vincenzi P;Agostinetti P;
2021

Abstract

A conceptual design and performance studies for a collimated neutron flux monitor and neutron spectrometer for the Divertor Tokamak Test (DTT) facility are presented. This study is based on the single-null divertor configuration and for "Half Power" and "Full power" scenarios with 15 MW of negative-ion NBI, 29 MW of ECH and 3 MW of ICRF heating with a maximum neutron yield of 1.5 × 1017 s- 1. Fast ion distributions (both from auxiliary heating systems and fusion born) have been simulated in TRANSP/NUBEAM and the corresponding neutron energy spectra have been calculated using DRESS. Synthetic diagnostics have been implemented to determine the neutron fluxes and spectra at the detector location. Neutron emissivity profiles, plasma position, core ion temperature and the ratio of thermal and non-thermal D ion populations can be obtained with good accuracy and time resolution.
2021
Istituto per la Scienza e Tecnologia dei Plasmi - ISTP
DTT
Radial neutron camera
Neutron spectrometer
Triton burnup
TRANSP/NUBEAM
DRESS
File in questo prodotto:
File Dimensione Formato  
prod_450173-doc_163027.pdf

solo utenti autorizzati

Descrizione: Conceptual design of a collimated neutron flux monitor and spectrometer for DTT
Tipologia: Versione Editoriale (PDF)
Dimensione 6.37 MB
Formato Adobe PDF
6.37 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/400379
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 1
social impact