Two common-path interferometers based on CO2 and Nd:VY3Al5O12 (Nd:YAG) lasers are benchmarked with a two-arm microwave interferometer on a hydrogen plasma produced by an RF discharge and injected into a large magnetic-confinement vessel. The similar to 10(19) m(-2) line-integrated electron density is clearly measured in agreement by the interferometers. The frequency spectrum of the measured data is analyzed on the 20 kHz range for all interferometers and up to 600 kHz for the Nd:YAG laser-based interferometer. Mechanical vibration measurements performed on the components of the two common-path interferometers result in a peak-to-peak displacement up to about one and twenty wavelengths for the CO2 and Nd:YAG laser-based interferometers, respectively. Such results set for the first time, to the best of our knowledge, a quantitative limit for the displacement that the two second-harmonic dispersion interferometers can sustain while still providing a high sensitivity for accurate plasma density measurements. (C) 2020 Optical Society of America
Experimental study on the performances of second-harmonic dispersion interferometers at 10.6 mu m and 1064 nm for plasma density measurements
Brandi Fernando;
2020
Abstract
Two common-path interferometers based on CO2 and Nd:VY3Al5O12 (Nd:YAG) lasers are benchmarked with a two-arm microwave interferometer on a hydrogen plasma produced by an RF discharge and injected into a large magnetic-confinement vessel. The similar to 10(19) m(-2) line-integrated electron density is clearly measured in agreement by the interferometers. The frequency spectrum of the measured data is analyzed on the 20 kHz range for all interferometers and up to 600 kHz for the Nd:YAG laser-based interferometer. Mechanical vibration measurements performed on the components of the two common-path interferometers result in a peak-to-peak displacement up to about one and twenty wavelengths for the CO2 and Nd:YAG laser-based interferometers, respectively. Such results set for the first time, to the best of our knowledge, a quantitative limit for the displacement that the two second-harmonic dispersion interferometers can sustain while still providing a high sensitivity for accurate plasma density measurements. (C) 2020 Optical Society of America| File | Dimensione | Formato | |
|---|---|---|---|
|
prod_450217-doc_177424.pdf
solo utenti autorizzati
Descrizione: Experimental study on the performances of second-harmonic dispersion interferometers at 10.6 µm and 1064 nm for plasma density measurements
Tipologia:
Versione Editoriale (PDF)
Licenza:
NON PUBBLICO - Accesso privato/ristretto
Dimensione
1.98 MB
Formato
Adobe PDF
|
1.98 MB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.