This paper presents a model based procedure for in situ error compensation of spatially distributed magnetic sensors. The proposed approach is numerically validated on RFX-mod, a magnetically confined plasma experiment presently being upgraded with a new magnetic diagnostic system and a state-of-the-art real time control system. The numerical simulations are performed with the CAFE code; synthetic measurements are used to assess the reliability of the proposed method.

Model Based Procedure for In Situ Error Compensation of Spatially Distributed Magnetic Sensors

Marrelli L;
2020

Abstract

This paper presents a model based procedure for in situ error compensation of spatially distributed magnetic sensors. The proposed approach is numerically validated on RFX-mod, a magnetically confined plasma experiment presently being upgraded with a new magnetic diagnostic system and a state-of-the-art real time control system. The numerical simulations are performed with the CAFE code; synthetic measurements are used to assess the reliability of the proposed method.
2020
Istituto per la Scienza e Tecnologia dei Plasmi - ISTP
9781728131238
Calibration
Error compensation
Magnetic confinement
Magnetic sensors
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.