An analysis of EMC standards related to smart grid devices with PLC port has been carried out and the standardization lacks have been pointed out with reference to the evaluation of electromagnetic immunity to narrowband, coming from other communication systems connected to the grid, and RF disturbances conducted disturbances, usually present in a power grid. In particular, the paper analyses the electromagnetic conducted immunity of a new interface protection device (ID) for smart grid and energy storage applications. The new ID is equipped with a measuring board, a STM32 microcontroller, for data elaboration and memorization, and a ST7580 N-PSK powerline transceiver. An experimental test procedure have been carried out in order to investigate the immunity of the ID prototype to narrowband and RF disturbances conducted disturbances, respectively for the frequency range 10-150 kHz and 150 kHz-30 MHz.

Electromagnetic Immunity Analysis of a New Interface Device with Power Line Communication for Smart Grid and Energy Storage Applications

D Di Cara;G Marsala;A Ragusa;G Tinè
2013

Abstract

An analysis of EMC standards related to smart grid devices with PLC port has been carried out and the standardization lacks have been pointed out with reference to the evaluation of electromagnetic immunity to narrowband, coming from other communication systems connected to the grid, and RF disturbances conducted disturbances, usually present in a power grid. In particular, the paper analyses the electromagnetic conducted immunity of a new interface protection device (ID) for smart grid and energy storage applications. The new ID is equipped with a measuring board, a STM32 microcontroller, for data elaboration and memorization, and a ST7580 N-PSK powerline transceiver. An experimental test procedure have been carried out in order to investigate the immunity of the ID prototype to narrowband and RF disturbances conducted disturbances, respectively for the frequency range 10-150 kHz and 150 kHz-30 MHz.
2013
Istituto di Studi sui Sistemi Intelligenti per l'Automazione - ISSIA - Sede Bari
978-1-4673-6015-9
carrier transmission on power lines
electromagnetic compatibility
energy storage
microcontrollers
smart power grids.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/4019
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 5
  • ???jsp.display-item.citation.isi??? 4
social impact