We have developed and tested a new way of coupling bolometric light detectors to scintillating crystal bolometers based upon simply resting the light detector on the crystal surface, held in position only by gravity. This straightforward mounting results in three important improvements: (1) it decreases the amount of non-active materials needed to assemble the detector, (2) it substantially increases the light collection efficiency by minimizing the light losses induced by the mounting structure, (3) and it enhances the thermal signal induced in the light detector thanks to the extremely weak thermal link to the thermal bath.We tested this new technique with a 16 cm(2) Ge light detector with thermistor readout sitting on the surface of a large TeO2 bolometer. The light collection efficiency was increased by greater than 50% compared to previously tested alternative mountings. We obtained a baseline energy resolution on the light detector of 20 eV RMS that, together with increased light collection, enabled us to obtain the best alpha vs beta/gamma discrimination ever obtained with massive TeO2 crystals. At the same time we achieved rise and decay times of 0.8 and 1.6 ms, respectively. This superb performance meets all of the requirements for the CUPID (CUORE Upgrade with Particle IDentification) experiment, which is a 1-ton scintillating bolometer follow up to CUORE.

Cryogenic light detectors with enhanced performance for rare event physics

Barucci M;
2019

Abstract

We have developed and tested a new way of coupling bolometric light detectors to scintillating crystal bolometers based upon simply resting the light detector on the crystal surface, held in position only by gravity. This straightforward mounting results in three important improvements: (1) it decreases the amount of non-active materials needed to assemble the detector, (2) it substantially increases the light collection efficiency by minimizing the light losses induced by the mounting structure, (3) and it enhances the thermal signal induced in the light detector thanks to the extremely weak thermal link to the thermal bath.We tested this new technique with a 16 cm(2) Ge light detector with thermistor readout sitting on the surface of a large TeO2 bolometer. The light collection efficiency was increased by greater than 50% compared to previously tested alternative mountings. We obtained a baseline energy resolution on the light detector of 20 eV RMS that, together with increased light collection, enabled us to obtain the best alpha vs beta/gamma discrimination ever obtained with massive TeO2 crystals. At the same time we achieved rise and decay times of 0.8 and 1.6 ms, respectively. This superb performance meets all of the requirements for the CUPID (CUORE Upgrade with Particle IDentification) experiment, which is a 1-ton scintillating bolometer follow up to CUORE.
2019
Istituto Nazionale di Ottica - INO
Double beta decay
Dark matter
Scintillating bolometers
Cherenkov radiation
Particle identification methods
Cryogenic detectors
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/403782
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 14
  • ???jsp.display-item.citation.isi??? ND
social impact