Measurement of pH is of fundamental importance in a wide range of environmental, biological and industrial applications. Glass electrode and litmus paper are widely used for this, but the former is difficult to miniaturize, prone to drift and fragile, the latter is inaccurate. This paper describes a pH sensor based on an indoaniline-derivative (4-((4-aminophenyl)imino)-2,6-dimethoxycyclohexa-2,5-dien-1-one), which exploits alternating current voltammetry to measure pH in the range between 2 and 12. The synthetized indoaniline-derivative was not genotoxic (A. cepa assay), and the sensor reliably measured pH in milk, tea, orange juice, blood, urine and saliva. Results were comparable with those obtained with a glass electrode calibrated with certified solutions (maximum relative standard deviation of 3 % and accuracy less than 0.2 pH unit). The sensor had negligible hysteresis, an almost Nernstian sensitivity (56 mV/pH) and was fully functional after a two-month storage. Sensor response showed a limited dependence on temperature (0.14 mV per pH unit and °C) and limited sensitivity to possible interferents such as lithium and sodium ions; its response to these was similar to that of a glass electrode, and was absent for ascorbic acid.

A voltammetric pH sensor for food and biological matrices

Salvo P;
2020

Abstract

Measurement of pH is of fundamental importance in a wide range of environmental, biological and industrial applications. Glass electrode and litmus paper are widely used for this, but the former is difficult to miniaturize, prone to drift and fragile, the latter is inaccurate. This paper describes a pH sensor based on an indoaniline-derivative (4-((4-aminophenyl)imino)-2,6-dimethoxycyclohexa-2,5-dien-1-one), which exploits alternating current voltammetry to measure pH in the range between 2 and 12. The synthetized indoaniline-derivative was not genotoxic (A. cepa assay), and the sensor reliably measured pH in milk, tea, orange juice, blood, urine and saliva. Results were comparable with those obtained with a glass electrode calibrated with certified solutions (maximum relative standard deviation of 3 % and accuracy less than 0.2 pH unit). The sensor had negligible hysteresis, an almost Nernstian sensitivity (56 mV/pH) and was fully functional after a two-month storage. Sensor response showed a limited dependence on temperature (0.14 mV per pH unit and °C) and limited sensitivity to possible interferents such as lithium and sodium ions; its response to these was similar to that of a glass electrode, and was absent for ascorbic acid.
2020
Istituto di Fisiologia Clinica - IFC
Biological fluids analysis
Food analysis
Indoaniline derivative
pH sensor
Voltammetric sensor
File in questo prodotto:
File Dimensione Formato  
39 A voltammetric pH sensor for food and biological matrices.pdf

solo utenti autorizzati

Descrizione: A voltammetric pH sensor for food and biological matrices
Tipologia: Versione Editoriale (PDF)
Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 2.62 MB
Formato Adobe PDF
2.62 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/404167
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 37
  • ???jsp.display-item.citation.isi??? 35
social impact