The two-dimensional (2D) density distribution of a particle beam can be reconstructed using a diagnostic based on tomographic techniques, which measures the D? light. This paper presents investigations and tests concerning the reliability of such a diagnostic, applied to the beam produced in MITICA (Megavolt ITER Injector & Concept Advancement) the full-size prototype of the neutral beam injector, which will be used for additional heating on ITER. It aims at developing the technologies to guarantee the correct operation of the injectors to be installed in ITER. The main target of the tomographic diagnostic is the measurement of the beam uniformity with sufficient contrast and spatial resolution, and of its evolution throughout the pulse duration. In particular the ITER beam uniformity is required to be within 10%, thus the error of the tomographic reconstruction has to be lower than this value. The conceptual design of the diagnostic is presented, with a description of the layout and main components. The portholes around the vessel and the geometry of the lines of sight are arranged so as to cover the whole area of the beam. A tomographic algorithm based on the simultaneous algebraic reconstruction technique (SART) is developed to reconstruct the beam intensity profile. Phantoms reproducing different experimental beam configurations are simulated and reconstructed with this technique. The role of noise in the line-integrated signals is studied and its effect on the reconstructed emission is investigated. The unsatisfactory results suggested the introduction of a regularization algorithm, to reduce the effect of the noise in the beam reconstruction. In this way, the simulated phantoms are correctly reconstructed and their 2D spatial non-uniformity is correctly estimated, up to a noise level of 10%.

The tomographic diagnostic of ITER neutral beam injector

M Brombin;M Agostini;R Pasqualotto;G Serianni;G Spizzo
2013

Abstract

The two-dimensional (2D) density distribution of a particle beam can be reconstructed using a diagnostic based on tomographic techniques, which measures the D? light. This paper presents investigations and tests concerning the reliability of such a diagnostic, applied to the beam produced in MITICA (Megavolt ITER Injector & Concept Advancement) the full-size prototype of the neutral beam injector, which will be used for additional heating on ITER. It aims at developing the technologies to guarantee the correct operation of the injectors to be installed in ITER. The main target of the tomographic diagnostic is the measurement of the beam uniformity with sufficient contrast and spatial resolution, and of its evolution throughout the pulse duration. In particular the ITER beam uniformity is required to be within 10%, thus the error of the tomographic reconstruction has to be lower than this value. The conceptual design of the diagnostic is presented, with a description of the layout and main components. The portholes around the vessel and the geometry of the lines of sight are arranged so as to cover the whole area of the beam. A tomographic algorithm based on the simultaneous algebraic reconstruction technique (SART) is developed to reconstruct the beam intensity profile. Phantoms reproducing different experimental beam configurations are simulated and reconstructed with this technique. The role of noise in the line-integrated signals is studied and its effect on the reconstructed emission is investigated. The unsatisfactory results suggested the introduction of a regularization algorithm, to reduce the effect of the noise in the beam reconstruction. In this way, the simulated phantoms are correctly reconstructed and their 2D spatial non-uniformity is correctly estimated, up to a noise level of 10%.
2013
Istituto gas ionizzati - IGI - Sede Padova
ALGEBRAIC RECONSTRUCTION TECHNIQUE
REVERSED-FIELD PINCH
RADIOLOGICAL APPLICATIONS
LINE INTEGRALS
LIMITED-DATA
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/4045
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 14
  • ???jsp.display-item.citation.isi??? 10