The role of the pedestal position on the pedestal performance has been investigated in AUG, JET-ILW and TCV. When the pedestal is peeling-ballooning (PB) limited, the three machines show a similar behaviour. The outward shift of the pedestal density relative to the pedestal temperature can lead to the outward shift of the pedestal pressure which, in turns, reduces the PB stability, degrades the pedestal confinement and reduces the pedestal width. Once the experimental density position is considered, the EPED model is able to correctly predict the pedestal height. An estimate of the impact of the density position on a ITER baseline scenario shows that the maximum reduction in the pedestal height is 10% while the reduction in the fusion power is between 10% and 40% depending on the assumptions for the core transport model used.In other plasmas, where the pedestal density is shifted even more outwards relative to the pedestal temperature, the pedestal does not seem PB limited and a different behaviour is observed. The outward shift of the density is still empirically correlated with the pedestal degradation but no change in the pressure position is observed and the PB model is not able to correctly predict the pedestal height. On the other hand, the outward shift of the density leads to a significant increase of eta(e) and eta(i) (where eta(e,i) is the ratio of density to temperature scale lengths, eta(e,i) = L-eta e,L-i/L-Te,L-i) which leads to the increase of the growth rate of microinstabilities (mainly ETG and ITG) by 50%. This suggests that, in these plasmas, the increase in the turbulent transport due to the outward shift of the density might play an important role in the decrease of the pedestal performance.

Role of the pedestal position on the pedestal performance in AUG, JET-ILW and TCV and implications for ITER

Alessi E;Brombin M;Carraro L;De Masi G;Gervasini G;Innocente P;Laguardia L;Marchetto C;Muraro A;Paccagnella R;Pasqualotto R;Pomaro N;Puiatti M E;Sozzi C;Tardocchi M;Terranova D;Uccello A;Vianello N;
2019

Abstract

The role of the pedestal position on the pedestal performance has been investigated in AUG, JET-ILW and TCV. When the pedestal is peeling-ballooning (PB) limited, the three machines show a similar behaviour. The outward shift of the pedestal density relative to the pedestal temperature can lead to the outward shift of the pedestal pressure which, in turns, reduces the PB stability, degrades the pedestal confinement and reduces the pedestal width. Once the experimental density position is considered, the EPED model is able to correctly predict the pedestal height. An estimate of the impact of the density position on a ITER baseline scenario shows that the maximum reduction in the pedestal height is 10% while the reduction in the fusion power is between 10% and 40% depending on the assumptions for the core transport model used.In other plasmas, where the pedestal density is shifted even more outwards relative to the pedestal temperature, the pedestal does not seem PB limited and a different behaviour is observed. The outward shift of the density is still empirically correlated with the pedestal degradation but no change in the pressure position is observed and the PB model is not able to correctly predict the pedestal height. On the other hand, the outward shift of the density leads to a significant increase of eta(e) and eta(i) (where eta(e,i) is the ratio of density to temperature scale lengths, eta(e,i) = L-eta e,L-i/L-Te,L-i) which leads to the increase of the growth rate of microinstabilities (mainly ETG and ITG) by 50%. This suggests that, in these plasmas, the increase in the turbulent transport due to the outward shift of the density might play an important role in the decrease of the pedestal performance.
2019
Istituto di fisica del plasma - IFP - Sede Milano
Istituto gas ionizzati - IGI - Sede Padova
Istituto per la Scienza e Tecnologia dei Plasmi - ISTP
pedestal
JET
AUG
TCV
stability
turbulent transport
EPED
File in questo prodotto:
File Dimensione Formato  
prod_430324-doc_153691.pdf

solo utenti autorizzati

Descrizione: Role of the pedestal position on the pedestal performance in AUG JET_ILW and TCV and implications for ITER
Tipologia: Versione Editoriale (PDF)
Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 2.29 MB
Formato Adobe PDF
2.29 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/404756
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 60
  • ???jsp.display-item.citation.isi??? 56
social impact