A nanoliquid chromatographic method for the stereoisomer separation of some flavanone aglycones and 7-O-glycosides has been proposed employing a C18 capillary column and a chiral mobile-phase additive such as cyclodextrin. The chiral separation of eriodictyol, naringenin, and hesperitin was obtained by addition of carboxymethyl-?-cyclodextrin to the mobile phase, whereas eriocitrin, naringin, narirutin, and hesperidin diastereoisomers were resolved by using sulfobutyl ether-?-cyclodextrin. The influence of the composition of the mobile phase, the length of the capillary column, and the flow rate on the chiral recognition were investigated. At optimum conditions, baseline separation for the selected aglycones and glycosylated forms were achieved with a mobile phase consisting of 50 mM sodium acetate buffer pH 3 and 30% methanol containing 20 mM of carboxymethyl-?-cyclodextrin and 10 mM of sulfobutyl ether-?-cyclodextrin, respectively. Precision, linearity, and sensitivity of the method were tested. Limits of detection and quantification for the studied flavanone glycosides were in the range 1.3-2.5 and 7.5-12.5 µg/mL, respectively. The method was used for the determination of the diastereomeric composition of the flavanone-7-O-glycosides in Citrus juices after solid-phase extraction procedure.

Stereoisomer separation of flavanones and flavanone-7-O-glycosides by means of nanoliquid chromatography employing derivatized ?-cyclodextrins as mobile-phase additive

Aturki Z;
2020

Abstract

A nanoliquid chromatographic method for the stereoisomer separation of some flavanone aglycones and 7-O-glycosides has been proposed employing a C18 capillary column and a chiral mobile-phase additive such as cyclodextrin. The chiral separation of eriodictyol, naringenin, and hesperitin was obtained by addition of carboxymethyl-?-cyclodextrin to the mobile phase, whereas eriocitrin, naringin, narirutin, and hesperidin diastereoisomers were resolved by using sulfobutyl ether-?-cyclodextrin. The influence of the composition of the mobile phase, the length of the capillary column, and the flow rate on the chiral recognition were investigated. At optimum conditions, baseline separation for the selected aglycones and glycosylated forms were achieved with a mobile phase consisting of 50 mM sodium acetate buffer pH 3 and 30% methanol containing 20 mM of carboxymethyl-?-cyclodextrin and 10 mM of sulfobutyl ether-?-cyclodextrin, respectively. Precision, linearity, and sensitivity of the method were tested. Limits of detection and quantification for the studied flavanone glycosides were in the range 1.3-2.5 and 7.5-12.5 µg/mL, respectively. The method was used for the determination of the diastereomeric composition of the flavanone-7-O-glycosides in Citrus juices after solid-phase extraction procedure.
2020
Istituto per i Sistemi Biologici - ISB (ex IMC)
chiral mobile phase additive
citrus juice
cyclodextrins
nano-liquid chromatography
stereoisomer separation
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/405282
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 14
  • ???jsp.display-item.citation.isi??? ND
social impact