The dynamic response of gas sensors based on poly(3-hexylthiophene) (P3HT) nanofibers (NFs) to gaseous acetone was assessed using a setup based on flow-injection analysis, aimed at emulating actual breath exhalation. The setup was validated by using a commercially available sensor. The P3HT NFs sensors tested in dynamic flow conditions showed satisfactory reproducibility down to about 3.5 ppm acetone concentration, a linear response over a clinically relevant concentration range (3.5-35 ppm), excellent baseline recovery and reversibility upon repeated exposures to the analyte, short pulse rise and fall times (less than 1 s and about 2 s, respectively) and low power consumption (few nW), with no relevant response to water. Comparable responses' decay times under either nitrogen or dry air suggest that the mechanisms at work is mainly attributable to specific analyte-semiconducting polymer interactions. These results open the way to the use of P3HT NFs-based sensing elements for the realization of portable, real-time electronic noses for on-the-fly exhaled breath analysis.

Nanostructured p3ht as a promising sensing element for real-time, dynamic detection of gaseous acetone

Dal Zilio S;
2019

Abstract

The dynamic response of gas sensors based on poly(3-hexylthiophene) (P3HT) nanofibers (NFs) to gaseous acetone was assessed using a setup based on flow-injection analysis, aimed at emulating actual breath exhalation. The setup was validated by using a commercially available sensor. The P3HT NFs sensors tested in dynamic flow conditions showed satisfactory reproducibility down to about 3.5 ppm acetone concentration, a linear response over a clinically relevant concentration range (3.5-35 ppm), excellent baseline recovery and reversibility upon repeated exposures to the analyte, short pulse rise and fall times (less than 1 s and about 2 s, respectively) and low power consumption (few nW), with no relevant response to water. Comparable responses' decay times under either nitrogen or dry air suggest that the mechanisms at work is mainly attributable to specific analyte-semiconducting polymer interactions. These results open the way to the use of P3HT NFs-based sensing elements for the realization of portable, real-time electronic noses for on-the-fly exhaled breath analysis.
2019
Istituto Officina dei Materiali - IOM -
-
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/405701
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 13
  • ???jsp.display-item.citation.isi??? ND
social impact