We report scanning Auger microscopy (SAM) and x-ray photoemission spectroscopy (XPS) analysis of a Roman lead pipe ''fistula'', the main emphasis being placed on the comparison between the surface and interface chemical composition of the joint and of the rest of the pipe. We find that the ''tertiarium,'' a Pb-Sn alloy that the Romans used for soldering the joint, has a beneficial effect in limiting the formation of white lead, 2PbCO(3).Pb(OH)(2). Comparison measurements performed in the alloy and the pure separate metals show that tin markedly limits the ambient surface oxdation of lead. Conversely, tin is much more oxidized in the alloy than when analysed alone. Auger point spectra indicate that carbon is the main surface contaminant of the patina of the fistula, and Auger imaging is used to pinpoint, with a spatial resolution of similar to 0.5 mu m, the distribution of this element at the interface of a lead/tertiarium solder, performed according to the procedures described by Plinius. The diagnostic capability of Auger transitions of lead and tin for distinguishing between different phases is discussed on the basis of their chemical shifts and surface sensitivities.

X-RAY PHOTOEMISSION SPECTROSCOPY AND SCANNING AUGER MICROSCOPY STUDIES OF A ROMAN LEAD PIPE FISTULA

PAPARAZZO E;
1995

Abstract

We report scanning Auger microscopy (SAM) and x-ray photoemission spectroscopy (XPS) analysis of a Roman lead pipe ''fistula'', the main emphasis being placed on the comparison between the surface and interface chemical composition of the joint and of the rest of the pipe. We find that the ''tertiarium,'' a Pb-Sn alloy that the Romans used for soldering the joint, has a beneficial effect in limiting the formation of white lead, 2PbCO(3).Pb(OH)(2). Comparison measurements performed in the alloy and the pure separate metals show that tin markedly limits the ambient surface oxdation of lead. Conversely, tin is much more oxidized in the alloy than when analysed alone. Auger point spectra indicate that carbon is the main surface contaminant of the patina of the fistula, and Auger imaging is used to pinpoint, with a spatial resolution of similar to 0.5 mu m, the distribution of this element at the interface of a lead/tertiarium solder, performed according to the procedures described by Plinius. The diagnostic capability of Auger transitions of lead and tin for distinguishing between different phases is discussed on the basis of their chemical shifts and surface sensitivities.
1995
XPS
SAM
Roman fistula
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/406913
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact