The application of this "best practice" in a case study in southern Latium where dramatic exceedances for Fe, Al, As, Mn in groundwater were reported, demonstrated how sampling procedures could have an important influence on analytical results, mainly the water filtration for inorganic compounds. In the case study, there were no exceedances of the CSC in the filtered samples, except for Mn in SV-PM1 well.

The notable differences observed in the analytical results for groundwater samples collected by different operators in several sites in Italy, pointed out the need for a standardized procedure for groundwater sampling at the national level. This "best practice" document, produced by IRSA-CNR and here described, aims to uniform the sampling procedures in order to have comparable results and to manage groundwater monitoring in a more participated and efficient manner. The proposed guideline underlines the relevance of the conceptual model implementation, as well as of the planning and sampling phases.

A proposal for groundwater sampling guidelines: application to a case study in southern Latium

Frollini Eleonora;Rossi David;Parrone Daniele;Ghergo Stefano;Preziosi Elisabetta
2019

Abstract

The notable differences observed in the analytical results for groundwater samples collected by different operators in several sites in Italy, pointed out the need for a standardized procedure for groundwater sampling at the national level. This "best practice" document, produced by IRSA-CNR and here described, aims to uniform the sampling procedures in order to have comparable results and to manage groundwater monitoring in a more participated and efficient manner. The proposed guideline underlines the relevance of the conceptual model implementation, as well as of the planning and sampling phases.
2019
The application of this "best practice" in a case study in southern Latium where dramatic exceedances for Fe, Al, As, Mn in groundwater were reported, demonstrated how sampling procedures could have an important influence on analytical results, mainly the water filtration for inorganic compounds. In the case study, there were no exceedances of the CSC in the filtered samples, except for Mn in SV-PM1 well.
sampling procedure
in-line filtration
monitoring
conceptual model
manganese
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/408115
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? 5
social impact