This work presents an experimental study focused on series arc faults detection in direct current (DC) photovoltaic (PV) systems [1]. The aim is to investigate the feasibility of using a set of indicators, which can be obtained by means of low frequency harmonic analysis of current signal. On field tests on a real PV system have been carried out, in accordance with some tests requirements of UL 1699B Standard for protection devices against PV DC arc faults [2]. Arcing and non-arcing current signals are acquired and compared and the behavior of a set of indicators proposed by authors is analyzed. Different measurement equipment has been used (including a commercial platform for mart metering applications, with embedded transducer and data acquisition), in order to study the impact of both measurement transducers and data acquisition systems on proposed indicators effectiveness. The comparison among the results obtained with different metering equipment allowed verifying the feasibility of using common smart metering platforms even for arc detection purposes.

DC SERIES ARC FAULT DETECTION IN PV SYSTEMS BASED ON LOW FREQUENCY HARMONIC ANALYSIS

D Di Cara;S Guaiana;N Panzavecchia;G Tinè;
2022

Abstract

This work presents an experimental study focused on series arc faults detection in direct current (DC) photovoltaic (PV) systems [1]. The aim is to investigate the feasibility of using a set of indicators, which can be obtained by means of low frequency harmonic analysis of current signal. On field tests on a real PV system have been carried out, in accordance with some tests requirements of UL 1699B Standard for protection devices against PV DC arc faults [2]. Arcing and non-arcing current signals are acquired and compared and the behavior of a set of indicators proposed by authors is analyzed. Different measurement equipment has been used (including a commercial platform for mart metering applications, with embedded transducer and data acquisition), in order to study the impact of both measurement transducers and data acquisition systems on proposed indicators effectiveness. The comparison among the results obtained with different metering equipment allowed verifying the feasibility of using common smart metering platforms even for arc detection purposes.
2022
Istituto di iNgegneria del Mare - INM (ex INSEAN)
Measuring systems and instrumentation
File in questo prodotto:
File Dimensione Formato  
prod_476991-doc_195130.pdf

solo utenti autorizzati

Descrizione: DC series arc fault detection in pv systems based on low frequency harmonic analysis
Tipologia: Versione Editoriale (PDF)
Dimensione 661.42 kB
Formato Adobe PDF
661.42 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/412707
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact