Among solar thermal collectors, the evacuated flat panel is emerging as a reference technology for operation at temperatures as high as 200 °C with an increased annual energy production owing to both direct and diffuse light capture. Accurate measurements of the optical properties of the selective absorbers used in such devices are key for a reliable estimation of the overall performance. These optical properties must be measured under high vacuum at high temperatures, conditions under which the panels are meant to operate. In this study, we accurately measured these properties using a calorimetric technique. The measurement procedure is based on a power balance equation for a flat sample absorber suspended in a high-vacuum chamber with minimized thermal losses and is well adapted for this class of devices. Calorimetric measurements obtained under Sun and LED light illumination revealed excellent reproducibility and good agreement with those obtained using traditional optical analysis at low temperatures in air. When extended up to the absorber stagnation temperature, which often exceeds 300 °C, the calorimetric measurements started to deviate from the optical measurements, indicating the importance of measuring under actual operating conditions.

Calorimetric testing of solar thermal absorbers for high vacuum flat panels

D'Alessandro Carmine;Caldarelli Antonio;Russo Roberto;
2022

Abstract

Among solar thermal collectors, the evacuated flat panel is emerging as a reference technology for operation at temperatures as high as 200 °C with an increased annual energy production owing to both direct and diffuse light capture. Accurate measurements of the optical properties of the selective absorbers used in such devices are key for a reliable estimation of the overall performance. These optical properties must be measured under high vacuum at high temperatures, conditions under which the panels are meant to operate. In this study, we accurately measured these properties using a calorimetric technique. The measurement procedure is based on a power balance equation for a flat sample absorber suspended in a high-vacuum chamber with minimized thermal losses and is well adapted for this class of devices. Calorimetric measurements obtained under Sun and LED light illumination revealed excellent reproducibility and good agreement with those obtained using traditional optical analysis at low temperatures in air. When extended up to the absorber stagnation temperature, which often exceeds 300 °C, the calorimetric measurements started to deviate from the optical measurements, indicating the importance of measuring under actual operating conditions.
2022
Istituto di Scienze Applicate e Sistemi Intelligenti "Eduardo Caianiello" - ISASI
Istituto Superconduttori, materiali innovativi e dispositivi - SPIN - Sede Secondaria Napoli
Calorimeter
Evacuated Flat Panel
High Vacuum Flat Panel
Selective Solar Absorber
Solar Absorptance
Solar Simulator
The
File in questo prodotto:
File Dimensione Formato  
prod_470371-doc_190767.pdf

solo utenti autorizzati

Descrizione: published version
Tipologia: Versione Editoriale (PDF)
Licenza: Creative commons
Dimensione 6.66 MB
Formato Adobe PDF
6.66 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/414024
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 7
  • ???jsp.display-item.citation.isi??? 5
social impact