Accurate isotopic composition analysis of the greenhouse-gasses emitted in the atmosphere is an important step to mitigate global climate warnings. Optical frequency comb-based spectroscopic techniques have shown ideal performance to accomplish the simultaneous monitoring of the different isotope substituted species of such gases. The capabilities of one such technique, namely, direct comb Vernier spectroscopy, to determine the fractional isotopic ratio composition are discussed. This technique combines interferometric filtering of the comb source in a Fabry-Perot that contains the sample gas, with a high resolution dispersion spectrometer to resolve the spectral content of each interacting frequency inside of the Fabry-Perot. Following this methodology, simultaneous spectra of ro-vibrational transitions of (CO2)-C-12-O-16 and (CO2)-C-13-O-16 molecules are recorded and analyzed with an accurate fitting procedure. Fractional isotopic ratio C-13/C-12 at 3% of precision is measured for a sample of CO2 gas, showing the potentialities of the technique for all isotopic-related applications of this important pollutant.

Direct Comb Vernier Spectroscopy for Fractional Isotopic Ratio Determinations

Eramo Roberto;
2021

Abstract

Accurate isotopic composition analysis of the greenhouse-gasses emitted in the atmosphere is an important step to mitigate global climate warnings. Optical frequency comb-based spectroscopic techniques have shown ideal performance to accomplish the simultaneous monitoring of the different isotope substituted species of such gases. The capabilities of one such technique, namely, direct comb Vernier spectroscopy, to determine the fractional isotopic ratio composition are discussed. This technique combines interferometric filtering of the comb source in a Fabry-Perot that contains the sample gas, with a high resolution dispersion spectrometer to resolve the spectral content of each interacting frequency inside of the Fabry-Perot. Following this methodology, simultaneous spectra of ro-vibrational transitions of (CO2)-C-12-O-16 and (CO2)-C-13-O-16 molecules are recorded and analyzed with an accurate fitting procedure. Fractional isotopic ratio C-13/C-12 at 3% of precision is measured for a sample of CO2 gas, showing the potentialities of the technique for all isotopic-related applications of this important pollutant.
2021
Istituto Nazionale di Ottica - INO
isotopic ratio; frequency comb; Vernier spectroscopy
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/419466
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? ND
social impact