Purpose To compare the performance US and MR in identifying placental adhesion spectrum (PAS) in placenta previa (PP) and to establish a potential method of image interpretation. Methods US and MR examinations of 51 patients with PP were selected. The presence of imaging signs commonly used to detect PAS was assessed. Penalized logistic regression was performed considering histology as standard of reference; only signs statistically significant (p < 0.05) were considered for ROC and multivariate analysis. The probability of PAS according to the presence of US and/or MR signs was then assessed. Results At univariate analysis, loss of retroplacental clear space, myometrial thinning (MT) and placenta lacunar spaces on US, intraplacental dark bands (IDBs), focal interruption of myometrial border (FIMB) and abnormal vascularity (AV) on MR were statistically significant (p < 0.01). Three diagnostic methods for PAS were then developed for both US and MR when at least one (Method 1), two (Method 2) or three (Method 3) imaging signs occurred, respectively. Method 2 for MR showed a significantly (p < 0.05) higher accuracy (91%) compared to the other methods. When MR IDBs and AV as well as IDBs and FIMB were present in combination with US MT the probability of PAS increased from 75 to 90% and from 80 to 91%, respectively. Conclusion MR demonstrated a higher diagnostic accuracy than US to detect PAS. However, since the combination of MR and US signs could improve the probability to detect PAS, a complementary diagnostic role of these techniques could be considered.

US and MR imaging findings to detect placental adhesion spectrum (PAS) in patients with placenta previa: a comparative systematic study

Mainenti P P;Liuzzi R;
2019

Abstract

Purpose To compare the performance US and MR in identifying placental adhesion spectrum (PAS) in placenta previa (PP) and to establish a potential method of image interpretation. Methods US and MR examinations of 51 patients with PP were selected. The presence of imaging signs commonly used to detect PAS was assessed. Penalized logistic regression was performed considering histology as standard of reference; only signs statistically significant (p < 0.05) were considered for ROC and multivariate analysis. The probability of PAS according to the presence of US and/or MR signs was then assessed. Results At univariate analysis, loss of retroplacental clear space, myometrial thinning (MT) and placenta lacunar spaces on US, intraplacental dark bands (IDBs), focal interruption of myometrial border (FIMB) and abnormal vascularity (AV) on MR were statistically significant (p < 0.01). Three diagnostic methods for PAS were then developed for both US and MR when at least one (Method 1), two (Method 2) or three (Method 3) imaging signs occurred, respectively. Method 2 for MR showed a significantly (p < 0.05) higher accuracy (91%) compared to the other methods. When MR IDBs and AV as well as IDBs and FIMB were present in combination with US MT the probability of PAS increased from 75 to 90% and from 80 to 91%, respectively. Conclusion MR demonstrated a higher diagnostic accuracy than US to detect PAS. However, since the combination of MR and US signs could improve the probability to detect PAS, a complementary diagnostic role of these techniques could be considered.
2019
Ultrasound (US)
Magnetic resonance imaging (MRI)
Placenta previa
Placental adhesion spectrum (PAS)
Diagnostic accuracy
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/421853
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact