Virtual reality (VR) headsets, with embedded micro-electromechanical systems, have the potential to assess the mechanical heart's functionality and respiratory activity in a non-intrusive way and without additional sensors by utilizing the ballistocardiographic principle. To test the feasibility of this approach for opportunistic physiological monitoring, thirty healthy volunteers were studied at rest in different body postures (sitting (SIT), standing (STAND) and supine (SUP)) while accelerometric and gyroscope data were recorded for 30 s using a VR headset (Oculus Go, Oculus, Microsoft, USA) simultaneously with a 1-lead electrocardiogram (ECG) signal for mean heart rate (HR) estimation. In addition, longer VR acquisitions (50 s) were performed under controlled breathing in the same three postures to estimate the respiratory rate (RESP). Three frequency-based methods were evaluated to extract from the power spectral density the corresponding frequency. By the obtained results, the gyroscope outperformed the accelerometer in terms of accuracy with the gold standard. As regards HR estimation, the best results were obtained in SIT, with Rs (95% confidence interval) = 0.91 (0.81-0.96) and bias (95% Limits of Agreement) -1.6 (5.4) bpm, followed by STAND, with Rs= 0.81 (0.64-0.91) and -1.7 (11.6) bpm, and SUP, with Rs = 0.44 (0.15-0.68) and 0.2 (19.4) bpm. For RESP rate estimation, SUP showed the best feasibility (98%) to obtain a reliable value from each gyroscope axis, leading to the identification of the transversal direction as the one containing the largest breathing information. These results provided evidence of the feasibility of the proposed approach with a degree of performance and feasibility dependent on the posture of the subject, under the conditions of keeping the head still, setting the grounds for future studies in real-world applications of HR and RESP rate measurement through VR headsets.

Feasibility of heart rate and respiratory rate estimation by inertial sensors embedded in a virtual reality headset

Solbiati S;Caiani EG
2020

Abstract

Virtual reality (VR) headsets, with embedded micro-electromechanical systems, have the potential to assess the mechanical heart's functionality and respiratory activity in a non-intrusive way and without additional sensors by utilizing the ballistocardiographic principle. To test the feasibility of this approach for opportunistic physiological monitoring, thirty healthy volunteers were studied at rest in different body postures (sitting (SIT), standing (STAND) and supine (SUP)) while accelerometric and gyroscope data were recorded for 30 s using a VR headset (Oculus Go, Oculus, Microsoft, USA) simultaneously with a 1-lead electrocardiogram (ECG) signal for mean heart rate (HR) estimation. In addition, longer VR acquisitions (50 s) were performed under controlled breathing in the same three postures to estimate the respiratory rate (RESP). Three frequency-based methods were evaluated to extract from the power spectral density the corresponding frequency. By the obtained results, the gyroscope outperformed the accelerometer in terms of accuracy with the gold standard. As regards HR estimation, the best results were obtained in SIT, with Rs (95% confidence interval) = 0.91 (0.81-0.96) and bias (95% Limits of Agreement) -1.6 (5.4) bpm, followed by STAND, with Rs= 0.81 (0.64-0.91) and -1.7 (11.6) bpm, and SUP, with Rs = 0.44 (0.15-0.68) and 0.2 (19.4) bpm. For RESP rate estimation, SUP showed the best feasibility (98%) to obtain a reliable value from each gyroscope axis, leading to the identification of the transversal direction as the one containing the largest breathing information. These results provided evidence of the feasibility of the proposed approach with a degree of performance and feasibility dependent on the posture of the subject, under the conditions of keeping the head still, setting the grounds for future studies in real-world applications of HR and RESP rate measurement through VR headsets.
2020
Istituto di Elettronica e di Ingegneria dell'Informazione e delle Telecomunicazioni - IEIIT
VR
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/422336
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 14
  • ???jsp.display-item.citation.isi??? ND
social impact