An optical platform for point of care testing (POCT) application is developed. The core of the platform is a miniaturised polymethylmetacrylate (PMMA) chip, that consists of two pieces of PMMA that have been custom-machined to produce flow channels, 500 ¼m in width and 400 ¼m in height, through which the analysed sample flows. Thanks to the fluorescence anisotropy, a large fraction of the fluorescence emitted by the sensing layer immobilised on the bottom of the PMMA cover travels along the thickness of the PMMA cover itself up to its end-face and it is collected by a plastic optical fibre connected to a photodetector. The potential of the optical chip is investigated with a sandwich assay for the C-reactive protein, one of the markers for inflammatory diseases. The assay covers the working range from 0.1 to 50 mg L-1 with a limit of detection of 0.004 mg L-1 working range. Different combinations of capture and target antibodies were carefully investigated in order to achieve the best performances in terms of sensitivity and unspecific adsorption

An optical PMMA biochip based on fluorescence anisotropy: application to C-reactive protein assay

2009

Abstract

An optical platform for point of care testing (POCT) application is developed. The core of the platform is a miniaturised polymethylmetacrylate (PMMA) chip, that consists of two pieces of PMMA that have been custom-machined to produce flow channels, 500 ¼m in width and 400 ¼m in height, through which the analysed sample flows. Thanks to the fluorescence anisotropy, a large fraction of the fluorescence emitted by the sensing layer immobilised on the bottom of the PMMA cover travels along the thickness of the PMMA cover itself up to its end-face and it is collected by a plastic optical fibre connected to a photodetector. The potential of the optical chip is investigated with a sandwich assay for the C-reactive protein, one of the markers for inflammatory diseases. The assay covers the working range from 0.1 to 50 mg L-1 with a limit of detection of 0.004 mg L-1 working range. Different combinations of capture and target antibodies were carefully investigated in order to achieve the best performances in terms of sensitivity and unspecific adsorption
2009
Istituto di Fisica Applicata - IFAC
Bioassay
CRP
Fluorescence anisotropy
Optical biochip
PMMA
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/42281
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 49
  • ???jsp.display-item.citation.isi??? ND
social impact