In concentrating solar systems, it is essential to study the optical losses of the collectors. A fundamental parameter is the intercept factor, namely, the fraction of sunrays reflected by the concentrator that reaches the receiver. Optical profilometry studies the relationship between the collector profile and the intercept factor, which influences the collection efficiency. Profilometric analyses were performed on a micro-parabolic trough collector (m-PTC), with reduced sizes and greater mirror curvature than a usual PTC. The proposed technique projects a luminous pattern (structured light) both on the collector with an opaque covering and on a flat reference plane. Measurement set-up and calibration technique were developed for m-PTC. A program coded in Python analyzed the images and reconstructs the mirror profile. The tilted reference plane was reconstructed using an original geometric model and a calibration procedure. The focal length of each parabolic section was calculated, providing information on surface defects in the mirror. An important parameter obtained was the displacement of the focus of the parabola with respect to the ideal position. Using this value, the intercept factor was estimated to be 0.89. The proposed technique was validated by comparing the results with an independent profilometric study applied to the same m-PTC.

Structured Light Profilometry on m-PTC

Marotta Gianluca;Sansoni Paola;Francini Franco;Jafrancesco David;Fontani Daniela
2020

Abstract

In concentrating solar systems, it is essential to study the optical losses of the collectors. A fundamental parameter is the intercept factor, namely, the fraction of sunrays reflected by the concentrator that reaches the receiver. Optical profilometry studies the relationship between the collector profile and the intercept factor, which influences the collection efficiency. Profilometric analyses were performed on a micro-parabolic trough collector (m-PTC), with reduced sizes and greater mirror curvature than a usual PTC. The proposed technique projects a luminous pattern (structured light) both on the collector with an opaque covering and on a flat reference plane. Measurement set-up and calibration technique were developed for m-PTC. A program coded in Python analyzed the images and reconstructs the mirror profile. The tilted reference plane was reconstructed using an original geometric model and a calibration procedure. The focal length of each parabolic section was calculated, providing information on surface defects in the mirror. An important parameter obtained was the displacement of the focus of the parabola with respect to the ideal position. Using this value, the intercept factor was estimated to be 0.89. The proposed technique was validated by comparing the results with an independent profilometric study applied to the same m-PTC.
2020
Istituto Nazionale di Ottica - INO
parabolic trough collectors
profilometry
structured light
intercept factor
optical measurement
solar energy
File in questo prodotto:
File Dimensione Formato  
prod_448316-doc_175997.pdf

accesso aperto

Descrizione: Structured Light Profilometry on m-PTC
Tipologia: Versione Editoriale (PDF)
Licenza: Creative commons
Dimensione 4.48 MB
Formato Adobe PDF
4.48 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/423163
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 3
  • ???jsp.display-item.citation.isi??? 3
social impact