Norovirus is one of the leading causes of gastroenteritis, acute vomiting, intense diarrhoea, acute pain in the stomach, high fever, headaches, and body pain. Conventional methods of detection gave us very promising results but had disadvantages such as low sensitivity, cost ineffectiveness, reduced specificity and selectivity, etc. Therefore, biosensors can be a viable alternative device which can overcome all setbacks associated with the conventional method. An electrochemical sensor based on oxidized graphitic carbon nitride (Ox-g-CN) modified electrochemical paper-based analytical device (ePAD) was fabricated for the detection of norovirus DNA. The synthesized Ox-g-CN nanosheets were characterized by field emission scanning electron microscopy (FESEM), X-ray Diffraction (XRD), UV-Vis spectroscopy and X-Ray Photoelectron Spectroscopy. The capture probe DNA (PDNA) modified electrodes were characterized by cyclic voltammetry (CV) and differential pulse voltammetry (DPV). These two characterization techniques were also employed to find the optimal scan rate, response time and temperature of the fabricated sensor. The fabricated biosensor showed a limit of detection (LOD) of 100 fM. Furthermore, the specificity of the reported biosensor was affirmed by testing the response of capture probe DNA with oxidized graphitic carbon nitride (PDNA/Ox-g-CN) modified ePAD on the introduction of a non-complimentary DNA. The fabricated ePAD sensor is easy to fabricate, cost effective and specific, and requires a minimum analysis time of 5 s.

Graphitic carbon nitride as an amplification platform on an electrochemical paper-based device for the detection of norovirus-specific DNA

Pilloton R
2020

Abstract

Norovirus is one of the leading causes of gastroenteritis, acute vomiting, intense diarrhoea, acute pain in the stomach, high fever, headaches, and body pain. Conventional methods of detection gave us very promising results but had disadvantages such as low sensitivity, cost ineffectiveness, reduced specificity and selectivity, etc. Therefore, biosensors can be a viable alternative device which can overcome all setbacks associated with the conventional method. An electrochemical sensor based on oxidized graphitic carbon nitride (Ox-g-CN) modified electrochemical paper-based analytical device (ePAD) was fabricated for the detection of norovirus DNA. The synthesized Ox-g-CN nanosheets were characterized by field emission scanning electron microscopy (FESEM), X-ray Diffraction (XRD), UV-Vis spectroscopy and X-Ray Photoelectron Spectroscopy. The capture probe DNA (PDNA) modified electrodes were characterized by cyclic voltammetry (CV) and differential pulse voltammetry (DPV). These two characterization techniques were also employed to find the optimal scan rate, response time and temperature of the fabricated sensor. The fabricated biosensor showed a limit of detection (LOD) of 100 fM. Furthermore, the specificity of the reported biosensor was affirmed by testing the response of capture probe DNA with oxidized graphitic carbon nitride (PDNA/Ox-g-CN) modified ePAD on the introduction of a non-complimentary DNA. The fabricated ePAD sensor is easy to fabricate, cost effective and specific, and requires a minimum analysis time of 5 s.
2020
Istituto di Cristallografia - IC
Graphitic Carbon Nitride
Amplification Platform
Electrochemical Paper-Based Biosensor
DN
Norovirus
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/423720
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 21
  • ???jsp.display-item.citation.isi??? ND
social impact