Brightness temperature values observed by satellite microwave radiometers are employed in Earth Observation (EO) mission to derive geophysical observables such as vapor and liquid integrated content, rainfall occurrence, sea surface temperature, and so on. The most common design for these radiometers is the total power scheme that requires - for the instrument calibration - targets with known and precise brightness temperature values. On board calibration relies on observations of hot and cold reference targets towards the "end to end" calibration of the receiver. Satellite-borne radiometers point at the cosmic space to mimic the cold reference target, whereas the hot reference is onboard. Additional calibration targets are generally required during the on-ground test to mimic both the scene and the cold sky in thermal vacuum chambers. This work is focused on the design, development and verification of the thermal vacuum cold target (TV-CT) for the Metop SG MicroWave Imager (MWI)

Thermal Vacuum Cold Target for the Metop SG MicroWave Imager

G Addamo;O A Peverini;AV Bosisio;
2020

Abstract

Brightness temperature values observed by satellite microwave radiometers are employed in Earth Observation (EO) mission to derive geophysical observables such as vapor and liquid integrated content, rainfall occurrence, sea surface temperature, and so on. The most common design for these radiometers is the total power scheme that requires - for the instrument calibration - targets with known and precise brightness temperature values. On board calibration relies on observations of hot and cold reference targets towards the "end to end" calibration of the receiver. Satellite-borne radiometers point at the cosmic space to mimic the cold reference target, whereas the hot reference is onboard. Additional calibration targets are generally required during the on-ground test to mimic both the scene and the cold sky in thermal vacuum chambers. This work is focused on the design, development and verification of the thermal vacuum cold target (TV-CT) for the Metop SG MicroWave Imager (MWI)
2020
Istituto di Elettronica e di Ingegneria dell'Informazione e delle Telecomunicazioni - IEIIT
microwave radiometry; calibration; pyramidal array; calibration target
thermal vacuum
MicroWave Imager
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/427081
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact