The new Muon g-2 experiment at Fermilab (E989) will measure the muon anomaly a(mu) = (g(mu) -2)/2 to an uncertainty of 16 x 10(-11) (0.14 ppm). The experiment is running with a positive muon beam. The decay positrons are detected by 24 electromagnetic calorimeters placed on the inner radius of the magnetic storage ring. As the gain fluctuation of each calorimeter channel must be corrected to a few parts in 10(4), a state-of-art laser calibration system has been realized which provides short laser pulses to the calorimeters. The monitoring of these light signals is done by specific photo-detectors read by a specialized Monitoring Electronics, which is organized in devoted crates and performs the full data acquisition of the calibration signals starting from pre-amplification, then digitization and finally transfer of the information. Here we describe few key elements of the whole system, namely the single readout channel of the Monitoring Board.

The monitoring electronics of the laser calibration system in the Muon g-2 experiment

Avino S;Ferrari C;Fioretti A;Gabbanini C;Gagliardi G;
2019

Abstract

The new Muon g-2 experiment at Fermilab (E989) will measure the muon anomaly a(mu) = (g(mu) -2)/2 to an uncertainty of 16 x 10(-11) (0.14 ppm). The experiment is running with a positive muon beam. The decay positrons are detected by 24 electromagnetic calorimeters placed on the inner radius of the magnetic storage ring. As the gain fluctuation of each calorimeter channel must be corrected to a few parts in 10(4), a state-of-art laser calibration system has been realized which provides short laser pulses to the calorimeters. The monitoring of these light signals is done by specific photo-detectors read by a specialized Monitoring Electronics, which is organized in devoted crates and performs the full data acquisition of the calibration signals starting from pre-amplification, then digitization and finally transfer of the information. Here we describe few key elements of the whole system, namely the single readout channel of the Monitoring Board.
2019
Istituto Nazionale di Ottica - INO
Laser calibration
Calorimetry
Front-end
DAQ
File in questo prodotto:
File Dimensione Formato  
prod_449285-doc_172054.pdf

solo utenti autorizzati

Descrizione: The monitoring electronics of the laser calibration system in the Muon g-2 experiment
Tipologia: Versione Editoriale (PDF)
Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 407.98 kB
Formato Adobe PDF
407.98 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.