Surface-plasmon resonance (SPR) sensors represent a formidable technology for molecular biology and bioanalytics applications. Here, we devise a new interrogation architecture that transforms a standard SPR chip into an optical-heterodyne clock detector comparable with the best SPR instruments. The key ingredients are (i) the conversion of refractive-index changes on the SPR chip into frequency shifts of an oscillatory electronic signal (ii) a differential probe & reference optical-cavity scheme that cancels out most source/detector noise contributions. A rigorous characterization of the sensor performance with the integration time demonstrates a refractive-index resolution on the 10-RIU level over a 1-s timescale using a bare, unstabilized SPR element. A bio-sensing test with a functionalized surface interfaced with a microfluidic flow-cell is carried out, showing detection of streptavidin via covalent bond down to concentrations of 90 fg/mm.

Surface-plasmon optical-heterodyne clock biosensor

Giorgini A;Avino S;Zullo R;De Natale P;Gagliardi G
2018

Abstract

Surface-plasmon resonance (SPR) sensors represent a formidable technology for molecular biology and bioanalytics applications. Here, we devise a new interrogation architecture that transforms a standard SPR chip into an optical-heterodyne clock detector comparable with the best SPR instruments. The key ingredients are (i) the conversion of refractive-index changes on the SPR chip into frequency shifts of an oscillatory electronic signal (ii) a differential probe & reference optical-cavity scheme that cancels out most source/detector noise contributions. A rigorous characterization of the sensor performance with the integration time demonstrates a refractive-index resolution on the 10-RIU level over a 1-s timescale using a bare, unstabilized SPR element. A bio-sensing test with a functionalized surface interfaced with a microfluidic flow-cell is carried out, showing detection of streptavidin via covalent bond down to concentrations of 90 fg/mm.
2018
Istituto Nazionale di Ottica - INO
Surface plasmon resonance
Biosensing
Optical resonator
Heterodyne detection
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/427898
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 11
  • ???jsp.display-item.citation.isi??? ND
social impact