At present, the only method for assessing the fusion power throughput of a reactor relies on the absolute measurement of 14 MeV neutrons produced in the D-T nuclear reaction. [1] For ITER and DEMO, however, at least another independent measurement of the fusion power is required. The 5Henucleus produced in the D-T fusion reaction has two de-excitation channels. The most likely is its disintegration in a particle and a neutron, D+T->5He->?+n, by means of the nuclear force. There is however also an electromagnetic channel, with a branching ratio ~10-5, which leads to the emission of a 17 MeV gamma-ray, i.e. D+T->5He*-> 5He+?. [2] The detection of this gamma-ray emission could serve as an independent method to determine the fusion power. In order to enable 17 MeV gamma-ray measurements, there is need for a detector with some coarse energy discrimination and, most importantly, capable to work in a neutron rich environment. Conventional inorganic scintillators, such as LaBr3(Ce), have comparable efficiencies to neutrons and gamma rays and they cannot be used for 17 MeV gamma-ray measurements without significant neutron shielding. In order to overcome this limitation, we here propose the conceptual design of a gamma ray counter with a variable energy threshold based on the Cherenkov effect and designed to operate in intense neutron fields. The detector geometry has been optimized using Geant4 so to achieve a gamma-ray to neutron efficiency ratio better than 105. The design is based on a gas Cherenkov detector and uses a CsI coated scintillating GEM (Gas Electron Multiplier) as photon pre-amplifier, together with a wavelength shifter to minimize the sensitivity to neutrons. Photons produced in the GEM are collected by an optical window and a bundle of optical fibers, which guides them towards an array of silicon photomultipliers (SiPMs) located further away from the plasma, in a region at low nuclear radiation.

Conceptual design of a Cherenkov based gamma-ray diagnostic for measurement of 17 MeV gamma rays from T(D, gamma)5He in magnetic confinement fusion plasmas

Muraro A;Grosso G;Perelli Cippo E;Rebai M;Tardocchi M
2021

Abstract

At present, the only method for assessing the fusion power throughput of a reactor relies on the absolute measurement of 14 MeV neutrons produced in the D-T nuclear reaction. [1] For ITER and DEMO, however, at least another independent measurement of the fusion power is required. The 5Henucleus produced in the D-T fusion reaction has two de-excitation channels. The most likely is its disintegration in a particle and a neutron, D+T->5He->?+n, by means of the nuclear force. There is however also an electromagnetic channel, with a branching ratio ~10-5, which leads to the emission of a 17 MeV gamma-ray, i.e. D+T->5He*-> 5He+?. [2] The detection of this gamma-ray emission could serve as an independent method to determine the fusion power. In order to enable 17 MeV gamma-ray measurements, there is need for a detector with some coarse energy discrimination and, most importantly, capable to work in a neutron rich environment. Conventional inorganic scintillators, such as LaBr3(Ce), have comparable efficiencies to neutrons and gamma rays and they cannot be used for 17 MeV gamma-ray measurements without significant neutron shielding. In order to overcome this limitation, we here propose the conceptual design of a gamma ray counter with a variable energy threshold based on the Cherenkov effect and designed to operate in intense neutron fields. The detector geometry has been optimized using Geant4 so to achieve a gamma-ray to neutron efficiency ratio better than 105. The design is based on a gas Cherenkov detector and uses a CsI coated scintillating GEM (Gas Electron Multiplier) as photon pre-amplifier, together with a wavelength shifter to minimize the sensitivity to neutrons. Photons produced in the GEM are collected by an optical window and a bundle of optical fibers, which guides them towards an array of silicon photomultipliers (SiPMs) located further away from the plasma, in a region at low nuclear radiation.
2021
Istituto per la Scienza e Tecnologia dei Plasmi - ISTP
gas Cherenkov detector
gamma-ray diagnostic
magnetic confinement
fusion plasmas
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/431596
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact