JET'snewMicrowaveAccesssystem requires a configurable interface to share the transmission lines between the various reflectometric instruments. A confocal quasi-opticalsystem made of modular blocks was designed and built for operation in the 60-160 GHz range, allowing full configuration and polarization flexibility. This paper deals with the design and test of the instrument.

Quasi-optical interface system for JET's new microwave access

Simonetto A;Sozzi C;Cirant S;Garavaglia S;Bruschi A;
2007

Abstract

JET'snewMicrowaveAccesssystem requires a configurable interface to share the transmission lines between the various reflectometric instruments. A confocal quasi-opticalsystem made of modular blocks was designed and built for operation in the 60-160 GHz range, allowing full configuration and polarization flexibility. This paper deals with the design and test of the instrument.
2007
Istituto di fisica del plasma - IFP - Sede Milano
Inglese
82
1
27
33
7
http://www.sciencedirect.com/science/article/pii/S092037960600144X
Sì, ma tipo non specificato
Diagnostics
Reflectometry
Quasi-optical systems
Millimeter waves
6
info:eu-repo/semantics/article
262
Simonetto, A; Sozzi, C; Cirant, S; Garavaglia, S; Bruschi, A; Jetefda, Contributors
01 Contributo su Rivista::01.01 Articolo in rivista
restricted
File in questo prodotto:
File Dimensione Formato  
prod_23189-doc_11835.pdf

solo utenti autorizzati

Descrizione: Quasi-optical interface system for JET's new microwave access
Tipologia: Versione Editoriale (PDF)
Dimensione 690.86 kB
Formato Adobe PDF
690.86 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/43168
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 3
  • ???jsp.display-item.citation.isi??? 2
social impact