The anticancer drug imatinib is often involved in therapeutic drug monitoring (TDM) studies aimed at improving the treatment of several forms of leukemia and gastrointestinal stromal tumors (GIST). To further implement the TDM of imatinib in clinical practice, we developed a detection assay by using an ssDNA aptamer, which demonstrated excellent selectivity and was not affected by interference from the components of human plasma samples. The efficient binding of imatinib to the aptamer was demonstrated by means of surface plasmon resonance (SPR) analysis, which allowed the development of a quantitative assay in the concentration range between 400 and 6000 ng mL(-1) (0.7-10 mu M), where a lower limit of quantification (LLOQ) of 400 ng mL(-1) was achieved. The precision of the assay was found to be within 12.0%, whereas the accuracy was in a range between 97.1 and 101.5%. The sample preparation procedure displayed a recovery in the range of 48.8-52.8%. Solid validation data were collected according to the regulatory guidelines and the method was compared with standard analytical techniques, leading to the development of a feasible aptasensor for the TDM of patients administered with imatinib.

An SPR investigation into the therapeutic drug monitoring of the anticancer drug imatinib with selective aptamers operating in human plasma

Tartaggia Stefano
;
2021

Abstract

The anticancer drug imatinib is often involved in therapeutic drug monitoring (TDM) studies aimed at improving the treatment of several forms of leukemia and gastrointestinal stromal tumors (GIST). To further implement the TDM of imatinib in clinical practice, we developed a detection assay by using an ssDNA aptamer, which demonstrated excellent selectivity and was not affected by interference from the components of human plasma samples. The efficient binding of imatinib to the aptamer was demonstrated by means of surface plasmon resonance (SPR) analysis, which allowed the development of a quantitative assay in the concentration range between 400 and 6000 ng mL(-1) (0.7-10 mu M), where a lower limit of quantification (LLOQ) of 400 ng mL(-1) was achieved. The precision of the assay was found to be within 12.0%, whereas the accuracy was in a range between 97.1 and 101.5%. The sample preparation procedure displayed a recovery in the range of 48.8-52.8%. Solid validation data were collected according to the regulatory guidelines and the method was compared with standard analytical techniques, leading to the development of a feasible aptasensor for the TDM of patients administered with imatinib.
2021
Istituto di Chimica Biomolecolare - ICB - Sede Secondaria Padova
Antineoplastic Agents; Drug Monitoring; Gastrointestinal Stromal Tumors; Humans; Imatinib Mesylate; Surface Plasmon Resonance
File in questo prodotto:
File Dimensione Formato  
prod_480417-doc_197328.pdf

solo utenti autorizzati

Descrizione: An SPR investigation into the therapeutic drug monitoring of the anticancer drug imatinib with selective aptamers operating in human plasma
Tipologia: Versione Editoriale (PDF)
Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 1.42 MB
Formato Adobe PDF
1.42 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
Analyst 2021 post print.pdf

Open Access dal 12/12/2021

Descrizione: An SPR investigation toward the therapeutic drug monitoring of anticancer drug imatinib with selective aptamers operating in human plasma
Tipologia: Documento in Post-print
Licenza: Creative commons
Dimensione 503.2 kB
Formato Adobe PDF
503.2 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/434732
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact