Objective: To assess whether different compact disk recording protocols, used to prepare speech test material, affect the reliability and comparability of speech audiometry testing. Material and methods: We conducted acoustic analysis of compact disks used in clinical practice, to determine whether speech material had been recorded using similar procedures. To assess the impact of different recording procedures on speech test outcomes, normal hearing subjects were tested using differently prepared compact disks, and their psychometric curves compared. Results: Acoustic analysis revealed that speech material had been recorded using different protocols. The major difference was the gain between the levels at which the speech material and the calibration signal had been recorded. Although correct calibration of the audiometer was performed for each compact disk before testing, speech recognition thresholds and maximum intelligibility thresholds differed significantly between compact disks (p < 0.05), and were influenced by the gain between the recording level of the speech material and the calibration signal. Conclusion: To ensure the reliability and comparability of speech test outcomes obtained using different compact disks, it is recommended to check for possible differences in the recording gains used to prepare the compact disks, and then to compensate for any differences before testing.

Influence of compact disk recording protocols on reliability and comparability of speech audiometry outcomes: acoustic analysis

2010

Abstract

Objective: To assess whether different compact disk recording protocols, used to prepare speech test material, affect the reliability and comparability of speech audiometry testing. Material and methods: We conducted acoustic analysis of compact disks used in clinical practice, to determine whether speech material had been recorded using similar procedures. To assess the impact of different recording procedures on speech test outcomes, normal hearing subjects were tested using differently prepared compact disks, and their psychometric curves compared. Results: Acoustic analysis revealed that speech material had been recorded using different protocols. The major difference was the gain between the levels at which the speech material and the calibration signal had been recorded. Although correct calibration of the audiometer was performed for each compact disk before testing, speech recognition thresholds and maximum intelligibility thresholds differed significantly between compact disks (p < 0.05), and were influenced by the gain between the recording level of the speech material and the calibration signal. Conclusion: To ensure the reliability and comparability of speech test outcomes obtained using different compact disks, it is recommended to check for possible differences in the recording gains used to prepare the compact disks, and then to compensate for any differences before testing.
2010
Istituto di Elettronica e di Ingegneria dell'Informazione e delle Telecomunicazioni - IEIIT
INGEGNERIA BIOMEDICA
speech audiometry
acoustic quantitative analysis
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/436835
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 3
social impact