A single-crystal diamond sample grown by high-pressure high-temperature (HPHT) technique was used for the fabrication of a metal-semiconductor-metal (MSM) photoconductor. The sample quality was evaluated by means of spectral photocurrent measurements highlighting the presence of a significant density of defect states within the diamond bandgap, responsible for trapmediated conduction mechanisms. The photoconductor was fully characterized under 6 MeV pulsed X-rays, sourced by a medical linear accelerator (LINAC), in the 0.05-20 Gy and 0.017-0.100 Gy/s dose (D) and dose-rate (DR) ranges, respectively. Photocurrent measurements performed with a conventional precision electrometer showed that the detector performance is strongly affected by charge-trapping phenomena, resulting in a sublinear dependence with the DR (power-law dependence with an exponent of 0.86). Measurements were repeated in the same experimental conditions by coupling the detector to a specifically developed gated integrator, allowing for a synchronous integration of photocurrent pulses (limited to 40 µs) centered on each impinging X-ray pulse. In this case, the detector photoresponse showed an excellent linearity with both the D and the DR (power-law dependence with 1.0009 ± 0.0004 and 1.009 ± 0.005 exponents, respectively). Significantly, the proposed synchronous integration technique is then able to mitigate the detrimental effect that defects have on detector performance. The proposed method paves, therefore, the way to the exploitation of HPHT diamond as a lowcost alternative to single-crystal chemical vapor deposition (CVD)-diamond for the fabrication of accurate and linear X-ray dosimeters.

Improving the Performance of HPHT-Diamond Detectors for Pulsed X-Ray Dosimetry Using the Synchronous Detection Technique

Marco Girolami;Daniele Maria Trucchi;
2023

Abstract

A single-crystal diamond sample grown by high-pressure high-temperature (HPHT) technique was used for the fabrication of a metal-semiconductor-metal (MSM) photoconductor. The sample quality was evaluated by means of spectral photocurrent measurements highlighting the presence of a significant density of defect states within the diamond bandgap, responsible for trapmediated conduction mechanisms. The photoconductor was fully characterized under 6 MeV pulsed X-rays, sourced by a medical linear accelerator (LINAC), in the 0.05-20 Gy and 0.017-0.100 Gy/s dose (D) and dose-rate (DR) ranges, respectively. Photocurrent measurements performed with a conventional precision electrometer showed that the detector performance is strongly affected by charge-trapping phenomena, resulting in a sublinear dependence with the DR (power-law dependence with an exponent of 0.86). Measurements were repeated in the same experimental conditions by coupling the detector to a specifically developed gated integrator, allowing for a synchronous integration of photocurrent pulses (limited to 40 µs) centered on each impinging X-ray pulse. In this case, the detector photoresponse showed an excellent linearity with both the D and the DR (power-law dependence with 1.0009 ± 0.0004 and 1.009 ± 0.005 exponents, respectively). Significantly, the proposed synchronous integration technique is then able to mitigate the detrimental effect that defects have on detector performance. The proposed method paves, therefore, the way to the exploitation of HPHT diamond as a lowcost alternative to single-crystal chemical vapor deposition (CVD)-diamond for the fabrication of accurate and linear X-ray dosimeters.
2023
Istituto di Struttura della Materia - ISM - Sede Roma Tor Vergata
Gated integrator
High-Pressure-High-Temperature (HPHT) diamond
Linear accelerators
LINAC
X-ray detectors
Radiation therapy
Radiotherapy
Diamond
File in questo prodotto:
File Dimensione Formato  
prod_478931-doc_196336.pdf

solo utenti autorizzati

Descrizione: published version
Tipologia: Versione Editoriale (PDF)
Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 2.02 MB
Formato Adobe PDF
2.02 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/437766
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 7
  • ???jsp.display-item.citation.isi??? ND
social impact