At present, the only method for assessing the fusion power throughput of a reactor relies on the absolute measurement of 14 MeV neutrons produced in the D-T nuclear reaction. For ITER and DEMO, however, at least another independent measurement of the fusion power is required. The 5He* nucleus produced in the D-T fusion reaction has two de-excitation channels. The most likely is its disintegration in an alpha particle and a neutron, D + T -> 5He* -> ? + n, by means of the nuclear force. There is however also an electromagnetic channel, with a branching ratio ~10-5, which leads to the emission of a 17 MeV gamma-ray, i.e. D + T -> 5He* -> 5He + ?. The detection of this gamma-ray emission could serve as an independent method to determine the fusion power. In order to enable 17 MeV gamma-ray measurements, there is need for a detector with some coarse energy discrimination and, most importantly, capable of working in a neutron-rich environment. Conventional inorganic scintillators, such as LaBr3(Ce), have comparable efficiencies to neutrons and gamma-rays and they cannot be used for 17 MeV gamma-ray measurements without significant neutron shielding. In order to overcome this limitation, we here propose the conceptual design of a gamma-ray counter with a variable energy threshold based on the Cherenkov effect and designed to operate in intense neutron fields. The detector geometry has been optimized using Geant4 so to achieve a gamma-ray to neutron efficiency ratio better than 105. The design is based on a gas Cherenkov detector and the photo-sensor is still to investigated.

Investigation of a Cherenkov-based gamma-ray diagnostic for measurement of 17 MeV gamma-rays from T(D, gamma)5 He in magnetic confinement fusion plasmas

Putignano O;Muraro A;Grosso G;Rebai M;Tardocchi M
2022

Abstract

At present, the only method for assessing the fusion power throughput of a reactor relies on the absolute measurement of 14 MeV neutrons produced in the D-T nuclear reaction. For ITER and DEMO, however, at least another independent measurement of the fusion power is required. The 5He* nucleus produced in the D-T fusion reaction has two de-excitation channels. The most likely is its disintegration in an alpha particle and a neutron, D + T -> 5He* -> ? + n, by means of the nuclear force. There is however also an electromagnetic channel, with a branching ratio ~10-5, which leads to the emission of a 17 MeV gamma-ray, i.e. D + T -> 5He* -> 5He + ?. The detection of this gamma-ray emission could serve as an independent method to determine the fusion power. In order to enable 17 MeV gamma-ray measurements, there is need for a detector with some coarse energy discrimination and, most importantly, capable of working in a neutron-rich environment. Conventional inorganic scintillators, such as LaBr3(Ce), have comparable efficiencies to neutrons and gamma-rays and they cannot be used for 17 MeV gamma-ray measurements without significant neutron shielding. In order to overcome this limitation, we here propose the conceptual design of a gamma-ray counter with a variable energy threshold based on the Cherenkov effect and designed to operate in intense neutron fields. The detector geometry has been optimized using Geant4 so to achieve a gamma-ray to neutron efficiency ratio better than 105. The design is based on a gas Cherenkov detector and the photo-sensor is still to investigated.
2022
Istituto per la Scienza e Tecnologia dei Plasmi - ISTP
Inglese
17
2
C02021-1
C02021-10
10
https://iopscience.iop.org/article/10.1088/1748-0221/17/02/C02021/meta
Sì, ma tipo non specificato
Cherenkov and transition radiation
Gaseous detectors
Nuclear instruments and methods for hot plasma diagnostics
Gamma detectors (scintillators CZT HPGe HgI etc.)
This work has been carried out within the framework of the EUROfusion consortium and has received funding from the Euratom research and training programme 2014-2018 and 2019-2020 under Grant Agreement No. 633053.
12
info:eu-repo/semantics/article
262
Putignano, O; Croci, G; Muraro, A; Cancelli, S; Giacomelli, L; Gorini, G; Grosso, G; Kushoro, Mh; Marcer, G; Nocente, M; Rebai, M; Tardocchi, M...espandi
01 Contributo su Rivista::01.01 Articolo in rivista
restricted
   Implementation of activities described in the Roadmap to Fusion during Horizon 2020 through a Joint programme of the members of the EUROfusion consortium
   EUROfusion
   H2020
   633053
File in questo prodotto:
File Dimensione Formato  
prod_464945-doc_182472.pdf

solo utenti autorizzati

Descrizione: Investigation of a Cherenkov-based gamma-ray diagnostic for measurement of 17 MeV gamma-rays
Tipologia: Versione Editoriale (PDF)
Dimensione 664.08 kB
Formato Adobe PDF
664.08 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/440148
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 4
  • ???jsp.display-item.citation.isi??? 4
social impact