Thermal ablation has been recognized as an effective method for liver malignancy treatment. The clinical difficulties lie in monitoring the treatment process in realtime. In recent years, microwave imaging has been proposed as a modality with out-standing features such as non-ionizing nature, cost-effective, and capable of realtime monitoring. In this respect, in this contribution, a low-complexity experimental set-up for the experimental assessment of microwave imaging system for liver ablation monitoring is proposed and numerically assessed. The reconstruction of images inside the liver shows that it is possible to localize the ablation zone in the abdomen phantom during the thermal ablation treatment. The results of this study lay the foundations for the experimental assessment of microwave imaging systems for thermal ablation monitoring.

Microwave imaging for liver thermal ablation monitoring: Developing an experimental set-up

Wang Mengchu;Scapaticci Rosa;Crocco Lorenzo;
2021

Abstract

Thermal ablation has been recognized as an effective method for liver malignancy treatment. The clinical difficulties lie in monitoring the treatment process in realtime. In recent years, microwave imaging has been proposed as a modality with out-standing features such as non-ionizing nature, cost-effective, and capable of realtime monitoring. In this respect, in this contribution, a low-complexity experimental set-up for the experimental assessment of microwave imaging system for liver ablation monitoring is proposed and numerically assessed. The reconstruction of images inside the liver shows that it is possible to localize the ablation zone in the abdomen phantom during the thermal ablation treatment. The results of this study lay the foundations for the experimental assessment of microwave imaging systems for thermal ablation monitoring.
2021
Istituto per il Rilevamento Elettromagnetico dell'Ambiente - IREA
Inglese
2021 XXXIVth General Assembly and Scientific Symposium of the International Union of Radio Science (URSI GASS)
9789463968027
http://www.scopus.com/record/display.url?eid=2-s2.0-85118261755&origin=inward
28/08/2021 - 04/09/2021
Rome
Liver
Microwave theory and techniques
Imaging phantoms
Monitoring
Image reconstruction
Microwave imaging
Abdomen
3
none
Wang, Mengchu; Scapaticci, Rosa; Crocco, Lorenzo; Cavagnaro, Marta
273
info:eu-repo/semantics/conferenceObject
04 Contributo in convegno::04.01 Contributo in Atti di convegno
   ElectroMagnetic imaging for a novel genERation of medicAL Devices
   EMERALD
   H2020
   764479
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/443300
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? ND
social impact