Green manuring of legume crops can improve soil fertility and sustainability. To evaluate its agronomic and environmental effectiveness, gaseous losses of ammonia (NH3) in the surface layer need to be quantified by direct measurements in the field. However, the application of the eddy-covariance technique to atmospheric NH3 is challenging: its high reactivity, water solubility, and low background concentrations all hinder the response time of closed-path sensors for fast measurements of NH3 concentration. Ammonia emissions following green manuring were measured for 21 days using a flux system equipped with a fast-pulsed quantum-cascade tunable-infrared-laser spectrometer. The noisy cross-covariance function for this configuration indicates flux measurements are close to the limit of detection; the low signal-to-noise ratio further increases the uncertainties, introducing a mirroring effect on the fluxes, which results in the rapid alternation between emission and deposition, within the limit of detection (around 13 and 20 ng m(-2) s(-1), at the 95 and 99% confidence limits, respectively). An evaluation of the measurement errors is presented, focussing on three technical aspects of the eddy-covariance system: (1) time lag, (2) random error, and (3) limit of detection. The NH3 fluxes measured by the spectrometer are close to its limit of detection, with a random error of the same order as the flux.

Limitations of an Eddy-Covariance System in Measuring Low Ammonia Fluxes

Di Tommasi Paul;Famulari Daniela;
2021

Abstract

Green manuring of legume crops can improve soil fertility and sustainability. To evaluate its agronomic and environmental effectiveness, gaseous losses of ammonia (NH3) in the surface layer need to be quantified by direct measurements in the field. However, the application of the eddy-covariance technique to atmospheric NH3 is challenging: its high reactivity, water solubility, and low background concentrations all hinder the response time of closed-path sensors for fast measurements of NH3 concentration. Ammonia emissions following green manuring were measured for 21 days using a flux system equipped with a fast-pulsed quantum-cascade tunable-infrared-laser spectrometer. The noisy cross-covariance function for this configuration indicates flux measurements are close to the limit of detection; the low signal-to-noise ratio further increases the uncertainties, introducing a mirroring effect on the fluxes, which results in the rapid alternation between emission and deposition, within the limit of detection (around 13 and 20 ng m(-2) s(-1), at the 95 and 99% confidence limits, respectively). An evaluation of the measurement errors is presented, focussing on three technical aspects of the eddy-covariance system: (1) time lag, (2) random error, and (3) limit of detection. The NH3 fluxes measured by the spectrometer are close to its limit of detection, with a random error of the same order as the flux.
2021
Istituto per i Sistemi Agricoli e Forestali del Mediterraneo - ISAFOM
Ammonia volatilization
Fast-pulsed quantum-cascade laser
Limit of detection
Time lag
White noise
File in questo prodotto:
File Dimensione Formato  
prod_462306-doc_182006.pdf

solo utenti autorizzati

Descrizione: Limitations of an Eddy-Covariance System in Measuring Low Ammonia Fluxes
Tipologia: Versione Editoriale (PDF)
Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 1.23 MB
Formato Adobe PDF
1.23 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/443404
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 5
  • ???jsp.display-item.citation.isi??? 5
social impact