Positronium beam formation and manipulation are required in several fundamental experiments. Efficient positron/positronium conversion in transmission configuration would offer important geometrical advantages over the reflection one for these applications. A novel type of transmission positron/positronium converters, which consists of silicon membranes with pass-through nanochannels, was produced and tested. The amount of forward emitted positronium was studied as a function of the thickness of the membranes and the nanochannel size. A maximum of, at least, (16±4)% of positrons implanted in (3.5±0.5)-?m-thick membrane with a nanochannel size of 5-8 nm were found to be forward emitted as positronium. A similar maximum amount of, at least, (16±5)%, was found to be emitted from a membrane (7.7±1.3)-?m-thick with a nanochannel size of 7-10 nm. A preliminary evaluation shows that the maximum amount of forward emitted positronium with the entire kinetic energy distribution below 1 eV is, at least, 9% of the positrons implanted in the (3.5±0.5)-?m-thick membrane.

Forward emission of positronium from nanochanneled silicon membranes

2022

Abstract

Positronium beam formation and manipulation are required in several fundamental experiments. Efficient positron/positronium conversion in transmission configuration would offer important geometrical advantages over the reflection one for these applications. A novel type of transmission positron/positronium converters, which consists of silicon membranes with pass-through nanochannels, was produced and tested. The amount of forward emitted positronium was studied as a function of the thickness of the membranes and the nanochannel size. A maximum of, at least, (16±4)% of positrons implanted in (3.5±0.5)-?m-thick membrane with a nanochannel size of 5-8 nm were found to be forward emitted as positronium. A similar maximum amount of, at least, (16±5)%, was found to be emitted from a membrane (7.7±1.3)-?m-thick with a nanochannel size of 7-10 nm. A preliminary evaluation shows that the maximum amount of forward emitted positronium with the entire kinetic energy distribution below 1 eV is, at least, 9% of the positrons implanted in the (3.5±0.5)-?m-thick membrane.
2022
Istituto Nanoscienze - NANO
Inglese
105
11
115422-1
115422-14
14
https://journals.aps.org/prb/abstract/10.1103/PhysRevB.105.115422#:~:text=The%20amount%20of%20forward%20emitted,be%20forward%20emitted%20as%20positronium.
Sì, ma tipo non specificato
---
10
info:eu-repo/semantics/article
262
Mariazzi, S; Rienacker, B; Magrin Maffei, R; Povolo, L; Sharma, S; Caravita, R; Penasa, L; Bettotti, P; Doser, M; Brusa, Rs
01 Contributo su Rivista::01.01 Articolo in rivista
none
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/444233
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 12
  • ???jsp.display-item.citation.isi??? ND
social impact