The separation of 11 phthalic acid ester (PAEs) was carried out by nano-liquid chromatography coupled to ultraviolet and MS detection. Preliminary experiments were achieved in order to select suitable stationary phases and chromatographic conditions. The baseline separation was obtained, for all compounds, with an XBridge(TM) C-18 column in less than 15 min, working in step gradient mode. The sensitivity of the method was improved by on-column focusing. PAEs were extracted from alcoholic and nonalcoholic beverages using vortex-assisted emulsification dispersive liquid-liquid microextration and natural deep eutectic solvents. The whole method was validated in terms of linearity, sensitivity, precision, recovery, and repeatability. Combination of both off-line sample preparation preconcentration and large injection volume led to obtain LOQs in the range 5-47 ng/mL. The developed nano-LC-UV method was extended to MS detection to confirm the presence of PAEs in some beverages commercialized in different types of packaging.

Nano-liquid chromatography combined with a sustainable microextraction based on natural deep eutectic solvents for analysis of phthalate esters

D'Orazio G.
2020

Abstract

The separation of 11 phthalic acid ester (PAEs) was carried out by nano-liquid chromatography coupled to ultraviolet and MS detection. Preliminary experiments were achieved in order to select suitable stationary phases and chromatographic conditions. The baseline separation was obtained, for all compounds, with an XBridge(TM) C-18 column in less than 15 min, working in step gradient mode. The sensitivity of the method was improved by on-column focusing. PAEs were extracted from alcoholic and nonalcoholic beverages using vortex-assisted emulsification dispersive liquid-liquid microextration and natural deep eutectic solvents. The whole method was validated in terms of linearity, sensitivity, precision, recovery, and repeatability. Combination of both off-line sample preparation preconcentration and large injection volume led to obtain LOQs in the range 5-47 ng/mL. The developed nano-LC-UV method was extended to MS detection to confirm the presence of PAEs in some beverages commercialized in different types of packaging.
2020
Istituto per i Sistemi Biologici - ISB (ex IMC)
Deep eutectic solvent
MS
nano LC
Phthalates
Wine
File in questo prodotto:
File Dimensione Formato  
G D_Orazio_Nano-liquid chromatography combined with a sustainable microextraction_446619_2020.pdf

solo utenti autorizzati

Tipologia: Versione Editoriale (PDF)
Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 383.48 kB
Formato Adobe PDF
383.48 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/446619
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 25
  • ???jsp.display-item.citation.isi??? 21
social impact