The indirect resolution of five beta-adrenoreceptor blocking agents (propranolol, oxprenolol,pindolol, metoprolol, and atenolol) using precolumn derivatization with (1)-1-(9-fluorenyl)ethyl chloroformate (FLEC), and capillary electrochromatography (CEC)is reported. Three octadecylsilanized (ODS) silica gel-based stationary phases, differing in particle diameter and carbon surface density for suitability of determination of the enantiomeric composition of these substances in drugs and biological fluids,were studied. Under optimum separation conditions, all the investigated compounds were baseline-resolved within acceptable analysis times (i.e., between 10–16 min).The resolution values ranged between 1.80 and 1.14, and the separation factorswere in no case less than 1.07. The possible use of the developed CEC method for the determination of enantiomeric composition of b-adrenoreceptor blocking agents in drug substances was investigated. A study, in which the enantiomers of metoprolol were examined regarding specificity, reproducibility, limit of detection, and ruggedness,was developed in accordance with some analytical procedures for method validation.

Indirect resolution of beta-blocker agents by reversed-phase capillary electrochromatography

Zeineb Aturki;Massimo Sinibaldi
2004

Abstract

The indirect resolution of five beta-adrenoreceptor blocking agents (propranolol, oxprenolol,pindolol, metoprolol, and atenolol) using precolumn derivatization with (1)-1-(9-fluorenyl)ethyl chloroformate (FLEC), and capillary electrochromatography (CEC)is reported. Three octadecylsilanized (ODS) silica gel-based stationary phases, differing in particle diameter and carbon surface density for suitability of determination of the enantiomeric composition of these substances in drugs and biological fluids,were studied. Under optimum separation conditions, all the investigated compounds were baseline-resolved within acceptable analysis times (i.e., between 10–16 min).The resolution values ranged between 1.80 and 1.14, and the separation factorswere in no case less than 1.07. The possible use of the developed CEC method for the determination of enantiomeric composition of b-adrenoreceptor blocking agents in drug substances was investigated. A study, in which the enantiomers of metoprolol were examined regarding specificity, reproducibility, limit of detection, and ruggedness,was developed in accordance with some analytical procedures for method validation.
2004
Istituto per i Sistemi Biologici - ISB (ex IMC)
beta-blockers agents
capillary electrochromatography
indirect resolution
reversed phase column
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/44784
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact