Background: Deep dental cavities can be restored through a single step according to the bulk-fill technique. Due to the great amount of resin to be cured, a main concern is the temperature rise occurring in the pulp chamber, potentially higher than that developed through the incremental layering technique. Temperature rise of bulk-fill composites have been evaluated. Methods: Bulk-fill composites, differing in material composition and viscosity, were used. Maximum temperature and temperature rate occurring in the composites were measured. Mesio-occlusal-distal cavities of human premolars were restored through the bulk-fill or the incremental layering techniques, and peak temperature and temperature rate occurring in the dentin, 1 mm below the cavity floor, were evaluated. Results: Temperature peak and temperature rise of flowable composites were significantly higher (p < 0.05) than packable composites. For both the techniques, higher temperature peaks were recorded in the dentin for flowable composites. Peak temperatures higher than 42 C were recorded for the incremental layering technique considering flowable composites. Conclusions: For all the composites, the light curing modality of 1000 mW/cm for 20 s can be considered safe if the bulk-fill technique is performed. Instead, for the incremental layering technique, potentially dangerous temperature peaks have been recorded for flowable composites.

Effect of low and high viscosity composites on temperature rise of premolars restored through the bulk-fill and the incremental layering techniques

De Santis R;
2020

Abstract

Background: Deep dental cavities can be restored through a single step according to the bulk-fill technique. Due to the great amount of resin to be cured, a main concern is the temperature rise occurring in the pulp chamber, potentially higher than that developed through the incremental layering technique. Temperature rise of bulk-fill composites have been evaluated. Methods: Bulk-fill composites, differing in material composition and viscosity, were used. Maximum temperature and temperature rate occurring in the composites were measured. Mesio-occlusal-distal cavities of human premolars were restored through the bulk-fill or the incremental layering techniques, and peak temperature and temperature rate occurring in the dentin, 1 mm below the cavity floor, were evaluated. Results: Temperature peak and temperature rise of flowable composites were significantly higher (p < 0.05) than packable composites. For both the techniques, higher temperature peaks were recorded in the dentin for flowable composites. Peak temperatures higher than 42 C were recorded for the incremental layering technique considering flowable composites. Conclusions: For all the composites, the light curing modality of 1000 mW/cm for 20 s can be considered safe if the bulk-fill technique is performed. Instead, for the incremental layering technique, potentially dangerous temperature peaks have been recorded for flowable composites.
2020
Istituto per i Polimeri, Compositi e Biomateriali - IPCB
Bulk-fill composites
Incremental layering technique
Pulpar damage
Temperature rise
Thermocouple
File in questo prodotto:
File Dimensione Formato  
applsci-10-08041.pdf

accesso aperto

Tipologia: Versione Editoriale (PDF)
Licenza: Creative commons
Dimensione 1.61 MB
Formato Adobe PDF
1.61 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/448881
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact