Background: Reliable biomarkers for assessing the viability of the donor hearts undergoing ex vivo perfusion remain elusive. A unique feature of normothermic ex vivo perfusion on the TransMedics® Organ Care System (OCS(TM)) is that the donor heart is maintained in a beating state throughout the preservation period. We applied a video algorithm for an in vivo assessment of cardiac kinematics, video kinematic evaluation (Vi.Ki.E.), to the donor hearts undergoing ex vivo perfusion on the OCS(TM) to assess the feasibility of applying this algorithm in this setting.Methods: Healthy donor porcine hearts (n = 6) were procured from Yucatan pigs and underwent 2 h of normothermic ex vivo perfusion on the OCS(TM) device. During the preservation period, serial high-resolution videos were captured at 30 frames per second. Using Vi.Ki.E., we assessed the force, energy, contractility, and trajectory parameters of each heart.Results: There were no significant changes in any of the measured parameters of the heart on the OCS(TM) device over time as judged by linear regression analysis. Importantly, there were no significant changes in contractility during the duration of the preservation period (time 0-30 min, 918 ± 430 px/s; time 31-60 min, 1,386 ± 603 px/s; time 61-90 min, 1,299 ± 617 px/s; time 91-120 min, 1,535 ± 728 px/s). Similarly, there were no significant changes in the force, energy, or trajectory parameters. Post-transplantation echocardiograms demonstrated robust contractility of each allograft.Conclusion: Vi.Ki.E. assessment of the donor hearts undergoing ex vivo perfusion is feasible on the TransMedics OCS(TM), and we observed that the donor hearts maintain steady kinematic measurements throughout the duration.

Video analysis of ex vivo beating hearts during preservation on the TransMedics organ care system

Marie-Louise Bang;
2023

Abstract

Background: Reliable biomarkers for assessing the viability of the donor hearts undergoing ex vivo perfusion remain elusive. A unique feature of normothermic ex vivo perfusion on the TransMedics® Organ Care System (OCS(TM)) is that the donor heart is maintained in a beating state throughout the preservation period. We applied a video algorithm for an in vivo assessment of cardiac kinematics, video kinematic evaluation (Vi.Ki.E.), to the donor hearts undergoing ex vivo perfusion on the OCS(TM) to assess the feasibility of applying this algorithm in this setting.Methods: Healthy donor porcine hearts (n = 6) were procured from Yucatan pigs and underwent 2 h of normothermic ex vivo perfusion on the OCS(TM) device. During the preservation period, serial high-resolution videos were captured at 30 frames per second. Using Vi.Ki.E., we assessed the force, energy, contractility, and trajectory parameters of each heart.Results: There were no significant changes in any of the measured parameters of the heart on the OCS(TM) device over time as judged by linear regression analysis. Importantly, there were no significant changes in contractility during the duration of the preservation period (time 0-30 min, 918 ± 430 px/s; time 31-60 min, 1,386 ± 603 px/s; time 61-90 min, 1,299 ± 617 px/s; time 91-120 min, 1,535 ± 728 px/s). Similarly, there were no significant changes in the force, energy, or trajectory parameters. Post-transplantation echocardiograms demonstrated robust contractility of each allograft.Conclusion: Vi.Ki.E. assessment of the donor hearts undergoing ex vivo perfusion is feasible on the TransMedics OCS(TM), and we observed that the donor hearts maintain steady kinematic measurements throughout the duration.
2023
Istituto di Ricerca Genetica e Biomedica - IRGB
Inglese
10
1216917
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85164491529&doi=10.3389/fcvm.2023.1216917&partnerID=40&md5=824b72a95b50be1878238924a747fb4c
Sì, ma tipo non specificato
Biomarker
cardiac transplanation
ex vivo perfusion
kinematics
normothermic
video
Cited by: 3; All Open Access, Gold Open Access, Green Open Access
16
info:eu-repo/semantics/article
262
Mendiola Pla, Michelle; Berrettoni, Silvia; H Lee, Franklin; Rozzi, Giacomo; Marrano, Federica; T Gross, Ryan; Evans, Amy; C Wendell, David; Lezberg, ...espandi
01 Contributo su Rivista::01.01 Articolo in rivista
none
   Stratification of heart failure patients for cardiac recovery upon cardiac unloading by left ventricular assist device therapy: addressing the molecular, epigenetic, and proteomic changes associated with reverse cardiac remodelling
   LVADStrat
   EraPerMed
   ERAPERMED2018-271
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/450176
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 5
  • ???jsp.display-item.citation.isi??? 6
social impact