In today's medicine, the celerity of the bio-assays analysis is crucial for the timely selection of the appropriate therapy and hence its effectiveness, especially in case of diseases characterized by the late onset of symptoms. In this paper, a lens-less fiber optics-based fluorescence sensor designed for the measurement of labeled bio-assays is presented and its potential for the early diagnosis of sepsis via C-reactive protein (CRP) detection is demonstrated. The sensor performance results from the combination of two key elements: a planar antenna that redirects fluorescence the marker emission and an automated fiber-based optical system for multi-spot analysis. First, the working principle of the device is demonstrated with a well-established antibody-antigen format (immunoglobulin IgG/anti-IgG assay), reporting more than one order of magnitude enhanced limit of detection (LOD) and limit of quantification (LOQ) for the planar antenna with respect to a standard glass substrate. The prototype is then tested against a sample mimicking a realistic case, prepared with commercially available human serum, showing a LOD and LOQ in the clinical range of interest (0.0015 ?g/mL and 0.005 ?g/mL, respectively) for the investigation of the sepsis biomarker CRP. These results validate the developed prototype as a simple and easy-to-operate device, compatible with standardized micro-well arrays, and potentially suitable for POC applications.

Enhanced Fluorescence in a Lens-Less Fiber-Optic Sensor for C-Reactive Protein Detection

Victoria Esteso;Pietro Lombardi
;
Francesco Chiavaioli;Prosenjit Majumder;Maja Colautti;Francesco Baldini;Ambra Giannetti;Costanza Toninelli
2023

Abstract

In today's medicine, the celerity of the bio-assays analysis is crucial for the timely selection of the appropriate therapy and hence its effectiveness, especially in case of diseases characterized by the late onset of symptoms. In this paper, a lens-less fiber optics-based fluorescence sensor designed for the measurement of labeled bio-assays is presented and its potential for the early diagnosis of sepsis via C-reactive protein (CRP) detection is demonstrated. The sensor performance results from the combination of two key elements: a planar antenna that redirects fluorescence the marker emission and an automated fiber-based optical system for multi-spot analysis. First, the working principle of the device is demonstrated with a well-established antibody-antigen format (immunoglobulin IgG/anti-IgG assay), reporting more than one order of magnitude enhanced limit of detection (LOD) and limit of quantification (LOQ) for the planar antenna with respect to a standard glass substrate. The prototype is then tested against a sample mimicking a realistic case, prepared with commercially available human serum, showing a LOD and LOQ in the clinical range of interest (0.0015 ?g/mL and 0.005 ?g/mL, respectively) for the investigation of the sepsis biomarker CRP. These results validate the developed prototype as a simple and easy-to-operate device, compatible with standardized micro-well arrays, and potentially suitable for POC applications.
2023
Istituto di Fisica Applicata - IFAC
Istituto Nazionale di Ottica - INO
ens-less light collection; fiber-based sensor; protein biomarker
File in questo prodotto:
File Dimensione Formato  
prod_491402-doc_204935.pdf

accesso aperto

Descrizione: Enhanced Fluorescence in a Lens-Less Fiber-Optic Sensor for C-Reactive Protein Detection
Tipologia: Versione Editoriale (PDF)
Licenza: Creative commons
Dimensione 1.87 MB
Formato Adobe PDF
1.87 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/450507
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 0
social impact