In today's medicine, the celerity of the bio-assays analysis is crucial for the timely selection of the appropriate therapy and hence its effectiveness, especially in case of diseases characterized by the late onset of symptoms. In this paper, a lens-less fiber optics-based fluorescence sensor designed for the measurement of labeled bio-assays is presented and its potential for the early diagnosis of sepsis via C-reactive protein (CRP) detection is demonstrated. The sensor performance results from the combination of two key elements: a planar antenna that redirects fluorescence the marker emission and an automated fiber-based optical system for multi-spot analysis. First, the working principle of the device is demonstrated with a well-established antibody-antigen format (immunoglobulin IgG/anti-IgG assay), reporting more than one order of magnitude enhanced limit of detection (LOD) and limit of quantification (LOQ) for the planar antenna with respect to a standard glass substrate. The prototype is then tested against a sample mimicking a realistic case, prepared with commercially available human serum, showing a LOD and LOQ in the clinical range of interest (0.0015 ?g/mL and 0.005 ?g/mL, respectively) for the investigation of the sepsis biomarker CRP. These results validate the developed prototype as a simple and easy-to-operate device, compatible with standardized micro-well arrays, and potentially suitable for POC applications.
Enhanced Fluorescence in a Lens-Less Fiber-Optic Sensor for C-Reactive Protein Detection
Victoria Esteso;Pietro Lombardi
;Francesco Chiavaioli;Prosenjit Majumder;Maja Colautti;Francesco Baldini;Ambra Giannetti;Costanza Toninelli
2023
Abstract
In today's medicine, the celerity of the bio-assays analysis is crucial for the timely selection of the appropriate therapy and hence its effectiveness, especially in case of diseases characterized by the late onset of symptoms. In this paper, a lens-less fiber optics-based fluorescence sensor designed for the measurement of labeled bio-assays is presented and its potential for the early diagnosis of sepsis via C-reactive protein (CRP) detection is demonstrated. The sensor performance results from the combination of two key elements: a planar antenna that redirects fluorescence the marker emission and an automated fiber-based optical system for multi-spot analysis. First, the working principle of the device is demonstrated with a well-established antibody-antigen format (immunoglobulin IgG/anti-IgG assay), reporting more than one order of magnitude enhanced limit of detection (LOD) and limit of quantification (LOQ) for the planar antenna with respect to a standard glass substrate. The prototype is then tested against a sample mimicking a realistic case, prepared with commercially available human serum, showing a LOD and LOQ in the clinical range of interest (0.0015 ?g/mL and 0.005 ?g/mL, respectively) for the investigation of the sepsis biomarker CRP. These results validate the developed prototype as a simple and easy-to-operate device, compatible with standardized micro-well arrays, and potentially suitable for POC applications.File | Dimensione | Formato | |
---|---|---|---|
prod_491402-doc_204935.pdf
accesso aperto
Descrizione: Enhanced Fluorescence in a Lens-Less Fiber-Optic Sensor for C-Reactive Protein Detection
Tipologia:
Versione Editoriale (PDF)
Licenza:
Creative commons
Dimensione
1.87 MB
Formato
Adobe PDF
|
1.87 MB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.