New polymeric macroporous materials based on poly 2-hydroxyethyl methacrylate (pHEMA) were synthesized and tested to adsorb CO. To this purpose, bio and affordable amine-based molecules such as lysine (LYS) and histidine (HIS) were selected as CO active sites and used to functionalize HEMA monomer before its crosslinking polymerization. The as-prepared monomers and polymers were characterized by using Nuclear Magnetic Resonance (NMR), Fourier Infrared Spectroscopy (FT-IR), Thermal gravimetric analysis (TGA), and Scanning Electron Microscopy (SEM) equipped with Energy Dispersive X-ray (EDX). Compared to materials reported in the recent literature, all produced ones provide exceptional adsorption capacity in the 162-193 ppm range. In particular, H-HEMA-LYS exhibits the best adsorption grade, well-fitting the Linear Driving Force (LFD) model. H-HEMA-LYS reusability was also tested for up to 5 cycles without significant loss in capture performance. Finally, to get insight into the role of morphology in CO adsorption, two diverse macroporous structures were synthesized (hydrogels and cryogels) for both HIS and LYS-based materials. As it turns out, hydrogel formulations of an average area ranging from 15.5 to 230 ?m adsorb 12% more than cryogels with higher values (266-605 ?m).
HEMA-based macro and microporous materials for CO2 capture
Dattilo Sandro
;Curcuruto Giusy;Mecca Tommaso;
2023
Abstract
New polymeric macroporous materials based on poly 2-hydroxyethyl methacrylate (pHEMA) were synthesized and tested to adsorb CO. To this purpose, bio and affordable amine-based molecules such as lysine (LYS) and histidine (HIS) were selected as CO active sites and used to functionalize HEMA monomer before its crosslinking polymerization. The as-prepared monomers and polymers were characterized by using Nuclear Magnetic Resonance (NMR), Fourier Infrared Spectroscopy (FT-IR), Thermal gravimetric analysis (TGA), and Scanning Electron Microscopy (SEM) equipped with Energy Dispersive X-ray (EDX). Compared to materials reported in the recent literature, all produced ones provide exceptional adsorption capacity in the 162-193 ppm range. In particular, H-HEMA-LYS exhibits the best adsorption grade, well-fitting the Linear Driving Force (LFD) model. H-HEMA-LYS reusability was also tested for up to 5 cycles without significant loss in capture performance. Finally, to get insight into the role of morphology in CO adsorption, two diverse macroporous structures were synthesized (hydrogels and cryogels) for both HIS and LYS-based materials. As it turns out, hydrogel formulations of an average area ranging from 15.5 to 230 ?m adsorb 12% more than cryogels with higher values (266-605 ?m).| File | Dimensione | Formato | |
|---|---|---|---|
|
prod_491523-doc_205001.pdf
accesso aperto
Descrizione: HEMA-based macro and microporous materials for CO2 capture
Tipologia:
Versione Editoriale (PDF)
Licenza:
Creative commons
Dimensione
4.1 MB
Formato
Adobe PDF
|
4.1 MB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.