Introduction: Biomarker testing is mandatory for the clinical management of patients with advanced non-small cell lung cancer (NSCLC). Myriads of technical platforms are now available for biomarker analysis with differences in terms of multiplexing capability, analytical sensitivity, and turnaround time (TAT). We evaluated the technical performance of the diagnostic workflows of 24 representative Italian institutions performing molecular tests on a series of artificial reference specimens built to mimic routine diagnostic samples. Methods: Sample sets of eight slides from cell blocks of artificial reference specimens harboring exon 19 EGFR (epidermal growth factor receptor) p.E746_AT50del, exon 2 KRAS (Kirsten rat sarcoma viral oncogene homologue) p.G12C, ROS1 (c-ros oncogene 1)-unknown gene fusion, and MET (MET proto-oncogene, receptor tyrosine kinase) ? exon 14 skipping were distributed to each participating institution. Two independent cell block specimens were validated by the University of Naples Federico II before shipment. Methodological and molecular data from reference specimens were annotated. Results: Overall, a median DNA concentration of 3.3 ng/µL (range 0.1-10.0 ng/µL) and 13.4 ng/µL (range 2.0-45.8 ng/µL) were obtained with automated and manual technical procedures, respectively. RNA concentrations of 5.7 ng/µL (range 0.2-11.9 ng/µL) and 9.3 ng/µL (range 0.5-18.0 ng/µL) were also detected. KRAS exon 2 p.G12C, EGFR exon 19 p.E736_A750del hotspot mutations, and ROS1 aberrant transcripts were identified in all tested cases, whereas 15 out of 16 (93.7%) centers detected MET exon 14 skipping mutation. Conclusions: Optimized technical workflows are crucial in the decision-making strategy of patients with NSCLC. Artificial reference specimens enable optimization of diagnostic workflows for predictive molecular analysis in routine clinical practice.

Non-Small Cell Lung Cancer Testing on Reference Specimens: An Italian Multicenter Experience

Giuseppe Diego Puglia;
2024

Abstract

Introduction: Biomarker testing is mandatory for the clinical management of patients with advanced non-small cell lung cancer (NSCLC). Myriads of technical platforms are now available for biomarker analysis with differences in terms of multiplexing capability, analytical sensitivity, and turnaround time (TAT). We evaluated the technical performance of the diagnostic workflows of 24 representative Italian institutions performing molecular tests on a series of artificial reference specimens built to mimic routine diagnostic samples. Methods: Sample sets of eight slides from cell blocks of artificial reference specimens harboring exon 19 EGFR (epidermal growth factor receptor) p.E746_AT50del, exon 2 KRAS (Kirsten rat sarcoma viral oncogene homologue) p.G12C, ROS1 (c-ros oncogene 1)-unknown gene fusion, and MET (MET proto-oncogene, receptor tyrosine kinase) ? exon 14 skipping were distributed to each participating institution. Two independent cell block specimens were validated by the University of Naples Federico II before shipment. Methodological and molecular data from reference specimens were annotated. Results: Overall, a median DNA concentration of 3.3 ng/µL (range 0.1-10.0 ng/µL) and 13.4 ng/µL (range 2.0-45.8 ng/µL) were obtained with automated and manual technical procedures, respectively. RNA concentrations of 5.7 ng/µL (range 0.2-11.9 ng/µL) and 9.3 ng/µL (range 0.5-18.0 ng/µL) were also detected. KRAS exon 2 p.G12C, EGFR exon 19 p.E736_A750del hotspot mutations, and ROS1 aberrant transcripts were identified in all tested cases, whereas 15 out of 16 (93.7%) centers detected MET exon 14 skipping mutation. Conclusions: Optimized technical workflows are crucial in the decision-making strategy of patients with NSCLC. Artificial reference specimens enable optimization of diagnostic workflows for predictive molecular analysis in routine clinical practice.
2024
Istituto per i Sistemi Agricoli e Forestali del Mediterraneo - ISAFOM
Inglese
12
1
73
95
23
https://link.springer.com/article/10.1007/s40487-023-00252-5
Sì, ma tipo non specificato
Lung
Molecular pathology
Tumor biomarker
This study has partly been supported by the following grants: 1. Monitoraggio ambientale, studio ed approfondimento della salute della popolazione residente in aree a rischio--In attuazione della D.G.R. Campanian.180/2019. 2. POR Campania FESR 2014-2020 Progetto "Sviluppo di Approcci Terapeutici Innovativi per patologie Neoplastiche resistenti ai trattamenti--SATIN" 3. The Italian Health Ministry's research program (ID: NET-2016-02363853). National Center for Gene Therapy and Drugs based on RNA Technology MUR-CN3 CUP E63C22000940007 to DS. No funding or sponsorship was received for the publication of this article. Open Access This article is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License, which permits any non-commercial use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder.
Internazionale
67
info:eu-repo/semantics/article
262
Pepe, Francesco; Russo, Gianluca; Venuta, Alessandro; Scimone, Claudia; Nacchio, Mariantonia; Pisapia, Pasquale; Goteri, Gaia; Barbisan, Francesca; Ch...espandi
01 Contributo su Rivista::01.01 Articolo in rivista
open
File in questo prodotto:
File Dimensione Formato  
Pepe_et_al-2024-Oncology_and_Therapy.pdf

accesso aperto

Descrizione: Non-Small Cell Lung Cancer Testing on Reference Specimens: An Italian Multicenter Experience
Tipologia: Versione Editoriale (PDF)
Licenza: Creative commons
Dimensione 944.07 kB
Formato Adobe PDF
944.07 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/452960
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 9
  • ???jsp.display-item.citation.isi??? 9
social impact