We used the eddy-covariance technique to measure the temporal dynamics and the relationships between leaf area index (LAI) and exchanges of carbon dioxide (CO), latent heat (LE) and sensible heat (H) in a multi-genotype short-rotation poplar coppice (SRC) located in East-Flanders (Belgium). The study was carried out over four years (2010-2013) corresponding to the first two rotations of the plantation. The net carbon (C) balance during the first two-year rotation was 75.2 (±4.4) gCm in the establishment year 2010 and -95.6 (±5.9) gCm in 2011. After the harvest (second two-year rotation) the coppice was a net source of carbon, 151.0 (±10.5) gCm in 2012, but a sink of -274.6 (±18.8) gCm in 2013. Overall, at the end of the second rotation this SRC, was a net CO sink with a cumulative uptake of -144.0 (±22.8) gCm. The temporal dynamics and the magnitude of the ratio between gross primary production (GPP) and ecosystem respiration (R) were similar to a deciduous forest. The evolution of LAI showed values ranging from 0.96 (±0.4) to 2.0 (±1.2) and from 5.1 (±1.5) to 4.5 (±0.84) during the first and the second rotation, respectively. The GPP (measured close to light saturation) was significantly related to LAI (r of 0.76, p<0.001). The cumulative evapotranspiration (ET) measured during the first rotation was 241.7mm and 349.9mm for 2010 and 2011, respectively, and 464.6mm and 372.1mm for 2012 and 2013. The average value of surface conductance (G) was 0.35molms and 0.24molms for the foliated and unfoliated periods, respectively. The mean decoupling factors (?) were 0.35 and 0.23 for the foliated and unfoliated periods, respectively, indicating that ET was primarily controlled by vapor pressure deficit (VPD) and G (a well-coupled system). The mean Priestley-Taylor coefficient (?) was 0.77 and 0.53 for the foliated and the unfoliated periods, respectively. Such low values indicate that ET was significantly lower than the equilibrium evaporation and thus also lower than the ET of a hypothetical reference crop. During the whole experiment only two short episodes of drought were identified when in May-June 2011 and June 2013 the evaporative fraction dropped below 0.4. The analysis of G showed a rather low stomatal control (anisohydric stomatal response) that put the poplar SRC at greater risk during severe drought conditions. All the three mentioned parameters related to ET and GPP (G, ? and ?) were significantly and positively correlated to LAI (r from 0.14 to 0.2, p<0.0001), suggesting that LAI was the main biophysical driver controlling the carbon and water balances in this bioenergy production system.

Biophysical drivers of the carbon dioxide, water vapor, and energy exchanges of a short-rotation poplar coppice

Zenone Terenzio;
2015

Abstract

We used the eddy-covariance technique to measure the temporal dynamics and the relationships between leaf area index (LAI) and exchanges of carbon dioxide (CO), latent heat (LE) and sensible heat (H) in a multi-genotype short-rotation poplar coppice (SRC) located in East-Flanders (Belgium). The study was carried out over four years (2010-2013) corresponding to the first two rotations of the plantation. The net carbon (C) balance during the first two-year rotation was 75.2 (±4.4) gCm in the establishment year 2010 and -95.6 (±5.9) gCm in 2011. After the harvest (second two-year rotation) the coppice was a net source of carbon, 151.0 (±10.5) gCm in 2012, but a sink of -274.6 (±18.8) gCm in 2013. Overall, at the end of the second rotation this SRC, was a net CO sink with a cumulative uptake of -144.0 (±22.8) gCm. The temporal dynamics and the magnitude of the ratio between gross primary production (GPP) and ecosystem respiration (R) were similar to a deciduous forest. The evolution of LAI showed values ranging from 0.96 (±0.4) to 2.0 (±1.2) and from 5.1 (±1.5) to 4.5 (±0.84) during the first and the second rotation, respectively. The GPP (measured close to light saturation) was significantly related to LAI (r of 0.76, p<0.001). The cumulative evapotranspiration (ET) measured during the first rotation was 241.7mm and 349.9mm for 2010 and 2011, respectively, and 464.6mm and 372.1mm for 2012 and 2013. The average value of surface conductance (G) was 0.35molms and 0.24molms for the foliated and unfoliated periods, respectively. The mean decoupling factors (?) were 0.35 and 0.23 for the foliated and unfoliated periods, respectively, indicating that ET was primarily controlled by vapor pressure deficit (VPD) and G (a well-coupled system). The mean Priestley-Taylor coefficient (?) was 0.77 and 0.53 for the foliated and the unfoliated periods, respectively. Such low values indicate that ET was significantly lower than the equilibrium evaporation and thus also lower than the ET of a hypothetical reference crop. During the whole experiment only two short episodes of drought were identified when in May-June 2011 and June 2013 the evaporative fraction dropped below 0.4. The analysis of G showed a rather low stomatal control (anisohydric stomatal response) that put the poplar SRC at greater risk during severe drought conditions. All the three mentioned parameters related to ET and GPP (G, ? and ?) were significantly and positively correlated to LAI (r from 0.14 to 0.2, p<0.0001), suggesting that LAI was the main biophysical driver controlling the carbon and water balances in this bioenergy production system.
2015
Bioenergy crop
Carbon uptake
Decoupling
Evapotranspiration
Leaf area index
Omega factor
Surface conductance
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/453536
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 36
  • ???jsp.display-item.citation.isi??? ND
social impact