SPIDER operation, started in 2018, pointed out performance-limiting issues caused by the technology employed in RF generators, based on tetrode free-running oscillators. One of these limits, namely the onset of frequency instabilities, prevented operation at the full rated power of 200 kW. In addition, tetrodes require high voltage to operate, which translates to risk of flashovers and the necessity to perform conditioning procedures, limiting the overall reliability. These disadvantages, combined with the positive experience gained in the meanwhile on smaller facilities with solid state amplifiers, led to the proposal of a complete re-design of the radiofrequency power supplies. This paper describes the modeling activities used to define specifications and design criteria of the solid-state amplifiers for SPIDER and MITICA, which can be directly transposed to the ITER HNB units when their functionality is proven. We detail the topology of the generators, consisting of class D amplifier modules combined to achieve the required 200 kW, which design is mainly driven by the necessity to deliver nominal power to the ion source, mitigate the risk of obsolescence, and improve the reliability through modularity. Due to the non-standard application, we gave particular focus to the integration of generators in the RF systems of SPIDER and MITICA. Numerical analyses were performed to verify the impact of harmonic distortion on transmission line and RF load components, to address the effect of mutual coupling between RF circuits on the generator output modulation, and to assess the magnitude of common mode currents in the electric system. These studies, as well as the experience gained from SPIDER operation, helped to define dedicated circuit design provisions and control strategies, which are currently being implemented in the detailed design and construction phase of the new RF amplifiers.

Integration studies of RF solid-state generators in the electrical system of NBTF experiments and ITER HNB

Recchia M;
2023

Abstract

SPIDER operation, started in 2018, pointed out performance-limiting issues caused by the technology employed in RF generators, based on tetrode free-running oscillators. One of these limits, namely the onset of frequency instabilities, prevented operation at the full rated power of 200 kW. In addition, tetrodes require high voltage to operate, which translates to risk of flashovers and the necessity to perform conditioning procedures, limiting the overall reliability. These disadvantages, combined with the positive experience gained in the meanwhile on smaller facilities with solid state amplifiers, led to the proposal of a complete re-design of the radiofrequency power supplies. This paper describes the modeling activities used to define specifications and design criteria of the solid-state amplifiers for SPIDER and MITICA, which can be directly transposed to the ITER HNB units when their functionality is proven. We detail the topology of the generators, consisting of class D amplifier modules combined to achieve the required 200 kW, which design is mainly driven by the necessity to deliver nominal power to the ion source, mitigate the risk of obsolescence, and improve the reliability through modularity. Due to the non-standard application, we gave particular focus to the integration of generators in the RF systems of SPIDER and MITICA. Numerical analyses were performed to verify the impact of harmonic distortion on transmission line and RF load components, to address the effect of mutual coupling between RF circuits on the generator output modulation, and to assess the magnitude of common mode currents in the electric system. These studies, as well as the experience gained from SPIDER operation, helped to define dedicated circuit design provisions and control strategies, which are currently being implemented in the detailed design and construction phase of the new RF amplifiers.
2023
Istituto per la Scienza e Tecnologia dei Plasmi - ISTP
Electric lines
Electric loads
Electric power transmission
Integrated circuit manufacture
Ion sources
Obsolescence
Power amplifiers
Timing circuits
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/456220
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 1
social impact