Nano-liquid chromatography (nano-LC) was used for the enantiomeric resolution of atenolol employing a teicoplanin modified silica stationary phase prepared in our laboratory. Experiments were carried out in a fused silica capillary of 75 mu m i.d. packed with chiral modified silica particles of 5 mu m diameter. Separated enantiomers were revealed by on-line UV detector at 205 nm or electrospray-ion-trap mass spectrometer (ESI-MS). Atenolol enantiomers were eluted utilizing a mobile phase with the following composition: 500 mM ammonium acetate pH 4.5/methanol/acetonitrile 1:60:39 (v/v/v) allowing to achieve good enantioresolution in a reasonable analysis time (about 8 min) with a flow rate of about 900 nL/min. After comparing the sensitivity of the nano-LC method using a conventional UV detector for capillary electrophoresis, a zeta cell (3 nL volume) employed in nano-LC and the ion-trap MS the method was validated with the MS detector offering the highest sensitivity (limit of detection (LOD) = 50 ng/mL; limit of quantification (LOQ) = 400 ng/mL for each atenolol enantiomer). (-)-Psi-Nor-ephedrine was used as the internal standard. The method was successfully applied to the analysis of atenolol enantiomers present in human urine samples of a patient under atenolol therapy. (c) 2005 Elsevier B.V. All rights reserved.

Use of teicoplanin stationary phase for the enantiomeric resolution of atenolol in human urine by nano-liquid chromatography-mass spectrometry

D'Orazio G;Fanali S
2006

Abstract

Nano-liquid chromatography (nano-LC) was used for the enantiomeric resolution of atenolol employing a teicoplanin modified silica stationary phase prepared in our laboratory. Experiments were carried out in a fused silica capillary of 75 mu m i.d. packed with chiral modified silica particles of 5 mu m diameter. Separated enantiomers were revealed by on-line UV detector at 205 nm or electrospray-ion-trap mass spectrometer (ESI-MS). Atenolol enantiomers were eluted utilizing a mobile phase with the following composition: 500 mM ammonium acetate pH 4.5/methanol/acetonitrile 1:60:39 (v/v/v) allowing to achieve good enantioresolution in a reasonable analysis time (about 8 min) with a flow rate of about 900 nL/min. After comparing the sensitivity of the nano-LC method using a conventional UV detector for capillary electrophoresis, a zeta cell (3 nL volume) employed in nano-LC and the ion-trap MS the method was validated with the MS detector offering the highest sensitivity (limit of detection (LOD) = 50 ng/mL; limit of quantification (LOQ) = 400 ng/mL for each atenolol enantiomer). (-)-Psi-Nor-ephedrine was used as the internal standard. The method was successfully applied to the analysis of atenolol enantiomers present in human urine samples of a patient under atenolol therapy. (c) 2005 Elsevier B.V. All rights reserved.
2006
Istituto per i Sistemi Biologici - ISB (ex IMC)
nano-liquid chromatography
enantiomers
chiral
drugs
teicoplanin
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/45662
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? 20
social impact