Various ways of application of radial electric field for the control of electrokinetic potential and EOF in a home-made device for CE are presented. The device comprises three highvoltage power supplies, which are used to form a radial electric field across the fused-silica capillary wall. One power supply provides the internal electric field – a driving force for electrophoretic migration of charged analytes and for the EOF. Two power supplies are connected to the ends of the outer low-conductivity polymeric coating, which is formed by the dispersion of insoluble conductive copolymer of aniline and p-phenylendiamine in polystyrene matrix (dissolved in N-methylpyrrolidone) attached to the original outer polyimide coating of the capillary. They are able to constitute the external longitudinal electric field with variable values of electric potential at both ends of the outer coating. The potential gradient between the external and internal electric field is perpendicular to the capillary wall and forms a radial electric field across the capillary wall, which affects the electrokinetic potential at the solid–liquid interface and EOF inside the capillary. The developed device and meth

Control of EOF in CE by different ways of application of radial electric field

Salvatore Fanali;Zeineb Aturki
2007

Abstract

Various ways of application of radial electric field for the control of electrokinetic potential and EOF in a home-made device for CE are presented. The device comprises three highvoltage power supplies, which are used to form a radial electric field across the fused-silica capillary wall. One power supply provides the internal electric field – a driving force for electrophoretic migration of charged analytes and for the EOF. Two power supplies are connected to the ends of the outer low-conductivity polymeric coating, which is formed by the dispersion of insoluble conductive copolymer of aniline and p-phenylendiamine in polystyrene matrix (dissolved in N-methylpyrrolidone) attached to the original outer polyimide coating of the capillary. They are able to constitute the external longitudinal electric field with variable values of electric potential at both ends of the outer coating. The potential gradient between the external and internal electric field is perpendicular to the capillary wall and forms a radial electric field across the capillary wall, which affects the electrokinetic potential at the solid–liquid interface and EOF inside the capillary. The developed device and meth
2007
Istituto per i Sistemi Biologici - ISB (ex IMC)
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/45681
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact