A quadrature optical detection technique, based on polarized balanced-homodyne interferometry, has been developed for specific application to apertureless near-field scanning optical microscopy (ANSOM). With such technique, multiplicative background interference, inficiating quantitative optical imaging in standard homodyne-based ANSOM, can be suppressed. Periodic modulation of interferometric optical phase, typically employed in heterodyne-based ANSOMs even to such purpose, is not needed in the present configuration. Homodyne detection also facilitates detection of harmonic components of the ANSOM optical signal at the probe/sample distance modulation frequency, necessary for near-field discrimination and suppression of artifacts. Furthermore, since amplitude signal is not affected by phase fluctuations generated in the optical path of the interferometer, an optical fiber could be included in one interferometer arm, to couple the ANSOM head to the detection system, obtaining improved versatility of the instrument. A demonstration of the interferometer performance is given by a test confocal optical scan of a mirror surface. This technique, as applied to near-field microscopy, is anticipated to provide absolute values of optical contrast not depending on background interference and topography artifacts. (C) 2008 American Institute of Physics.

Balanced homodyning for apertureless near-field optical imaging

Labardi M;Allegrini M
2008

Abstract

A quadrature optical detection technique, based on polarized balanced-homodyne interferometry, has been developed for specific application to apertureless near-field scanning optical microscopy (ANSOM). With such technique, multiplicative background interference, inficiating quantitative optical imaging in standard homodyne-based ANSOM, can be suppressed. Periodic modulation of interferometric optical phase, typically employed in heterodyne-based ANSOMs even to such purpose, is not needed in the present configuration. Homodyne detection also facilitates detection of harmonic components of the ANSOM optical signal at the probe/sample distance modulation frequency, necessary for near-field discrimination and suppression of artifacts. Furthermore, since amplitude signal is not affected by phase fluctuations generated in the optical path of the interferometer, an optical fiber could be included in one interferometer arm, to couple the ANSOM head to the detection system, obtaining improved versatility of the instrument. A demonstration of the interferometer performance is given by a test confocal optical scan of a mirror surface. This technique, as applied to near-field microscopy, is anticipated to provide absolute values of optical contrast not depending on background interference and topography artifacts. (C) 2008 American Institute of Physics.
2008
INFM
MICROSCOPY
RESOLUTION
CONTRAST
SCALE
TIP
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/457749
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact