This paper presents a comparative study of polymer pixel on sensors obtained by Laser Induced Forward Transfer (LIFT) assisted by a triazene polymer as Dynamic Release Layer (DRL). Polyisobutylene (PIB) was selected as model for chemoselective polymers which could be used as hydrogen-bond acidic polymer for vapor sensors. PIB films deposited on fused silica, respectively, on triazene polymer coated fused silica substrates were used as targets. Both targets were prepared by Matrix Assisted Pulsed Laser Evaporation (MAPLE). The parameters related to a regular, well-defined transfer were analyzed and compared for the substrates with and without the DRL. The morphological characterization of the transferred PIB was performed by Atomic Force Microscopy (AFM), Optical Microscopy, and Scanning Electron Microscopy (SEM). It was found that a minimal thickness of the dynamic release layer, i.e. 100 nm is required to protect the sensitive PIB polymer in a clean laser transfer process.

A comparative study of DRL-lift and lift on integrated polyisobutylene polymer matrices

F Di Pietrantonio;M Benetti;E Verona
2010

Abstract

This paper presents a comparative study of polymer pixel on sensors obtained by Laser Induced Forward Transfer (LIFT) assisted by a triazene polymer as Dynamic Release Layer (DRL). Polyisobutylene (PIB) was selected as model for chemoselective polymers which could be used as hydrogen-bond acidic polymer for vapor sensors. PIB films deposited on fused silica, respectively, on triazene polymer coated fused silica substrates were used as targets. Both targets were prepared by Matrix Assisted Pulsed Laser Evaporation (MAPLE). The parameters related to a regular, well-defined transfer were analyzed and compared for the substrates with and without the DRL. The morphological characterization of the transferred PIB was performed by Atomic Force Microscopy (AFM), Optical Microscopy, and Scanning Electron Microscopy (SEM). It was found that a minimal thickness of the dynamic release layer, i.e. 100 nm is required to protect the sensitive PIB polymer in a clean laser transfer process.
2010
Istituto di Acustica e Sensoristica - IDASC - Sede Roma Tor Vergata
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/457780
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? 16
social impact