Purpose: To assess the tissue iron concentration of the left ventricle (LV) using a multislice, multiecho T2* MR technique and a segmental analysis. Materials and Methods: T2* multiecho MRI was performed in 53 thalassemia major patients. Three short-axis views of the LV were obtained and analyzed with custom-written software. The myocardium was automatically segmented into 12 segments. The T2* value on each segment as well as the global T2* value were calculated. Cine dynamic images were also obtained to evaluate biventricular function parameters by quantitative analysis. Results: For the T2* global value, the coefficient of variation (CoV) for intra-/interobserver and interstudy reproducibility was 3.9% (r == 0.98), 5.5% (r = 0.98), and 4.7% (r == 0.99) respectively. Three groups were identified based on analysis of myocardial T2*: homogeneous (21%), heterogeneous (38%), and no myocardial iron overload (41%). The mean serum ferritin, liver iron concentration, and urinary iron excretion were significantly different among the groups. We did not find significant differences among groups in biventricular function. There was a correlation between the global T2* value and the T2* value in the mid-ventricular septum (r = 0.95, P 0.0001). Conclusion: Multislice multiecho T2* MRI provides a noninvasive, fast, reproducible means of assessing myocardial iron distribution. The single measurement of mid-septal T2* correlated well with the global T2* value.

Multislice Multiecho T2* Cardiovascular Magnetic Resonance for Detection of the Heterogeneous Distribution of Myocardial Iron Overload

Positano V;Santarelli M F;Landini L;
2006

Abstract

Purpose: To assess the tissue iron concentration of the left ventricle (LV) using a multislice, multiecho T2* MR technique and a segmental analysis. Materials and Methods: T2* multiecho MRI was performed in 53 thalassemia major patients. Three short-axis views of the LV were obtained and analyzed with custom-written software. The myocardium was automatically segmented into 12 segments. The T2* value on each segment as well as the global T2* value were calculated. Cine dynamic images were also obtained to evaluate biventricular function parameters by quantitative analysis. Results: For the T2* global value, the coefficient of variation (CoV) for intra-/interobserver and interstudy reproducibility was 3.9% (r == 0.98), 5.5% (r = 0.98), and 4.7% (r == 0.99) respectively. Three groups were identified based on analysis of myocardial T2*: homogeneous (21%), heterogeneous (38%), and no myocardial iron overload (41%). The mean serum ferritin, liver iron concentration, and urinary iron excretion were significantly different among the groups. We did not find significant differences among groups in biventricular function. There was a correlation between the global T2* value and the T2* value in the mid-ventricular septum (r = 0.95, P 0.0001). Conclusion: Multislice multiecho T2* MRI provides a noninvasive, fast, reproducible means of assessing myocardial iron distribution. The single measurement of mid-septal T2* correlated well with the global T2* value.
2006
Istituto di Fisiologia Clinica - IFC
cardiomyopathy
thalassemia
magnetic resonance imaging
iron overload
relaxation time (T2*)
File in questo prodotto:
File Dimensione Formato  
prod_23832-doc_13224.pdf

solo utenti autorizzati

Descrizione: Articolo Pubblicato
Dimensione 641.29 kB
Formato Adobe PDF
641.29 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/45960
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? 42
social impact